Implementation of Multi-Curie Production of <sup>99m</sup>Tc by Conventional Medical Cyclotrons
Notice bibliographique
Résumé
UNLABELLED: (99m)Tc is currently produced by an aging fleet of nuclear reactors, which require enriched uranium and generate nuclear waste. We report the development of a comprehensive solution to produce (99m)Tc in sufficient quantities to supply a large urban area using a single medical cyclotron. METHODS: A new target system was designed for (99m)Tc production. Target plates made of tantalum were coated with a layer of (100)Mo by electrophoretic deposition followed by high-temperature sintering. The targets were irradiated with 18-MeV protons for up to 6 h, using a medical cyclotron. The targets were automatically retrieved and dissolved in 30% H2O2. (99m)Tc was purified by solid-phase extraction or biphasic exchange chromatography. RESULTS: Between 1.04 and 1.5 g of (100)Mo were deposited on the tantalum plates. After high-temperature sintering, the (100)Mo formed a hard, adherent layer that bonded well with the backing surface. The targets were irradiated for 1-6.9 h at 20-240 μA of proton beam current, producing up to 348 GBq (9.4 Ci) of (99m)Tc. The resulting pertechnetate passed all standard quality control procedures and could be used to reconstitute typical anionic, cationic, and neutral technetium radiopharmaceutical kits. CONCLUSION: The direct production of (99m)Tc via proton bombardment of (100)Mo can be practically achieved in high yields using conventional medical cyclotrons. With some modifications of existing cyclotron infrastructure, this approach can be used to implement a decentralized medical isotope production model. This method eliminates the need for enriched uranium and the radioactive waste associated with the processing of uranium targets.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».