Fabrication and evaluation of an oxygen microelectrode applicable to environmental engineering and science
Notice bibliographique
Résumé
This paper introduces the fabrication procedure and evaluation method of an oxygen microelectrode applicable to environmental engineering and science research. The theory and development of an oxygen microelectrode technique are introduced. The fabrication procedure of a combined oxygen microelectrode with small-tip diameter (1520 μμm) is described in detail. This microelectrode was then evaluated by subjecting it to a polarization voltage of 0.8 V and calibrating against known dissolved oxygen concentrations from zero to air saturation. The results of the evaluation demonstrated that the fabrication procedure reported in this paper was successful. This microelectrode had a fast response time (<2 s), stable reading with good calibration linearity (R 2 = 1), low residual current signal (6 pA), and low stirring effect (4%). No electromagnetic interference was observed when this combined oxygen microelectrode was used under both laboratory and field conditions. The combined oxygen microelectrode fabricated using this procedure can be used for in situ measurement of dissolved oxygen in wastewater biofilms under field conditions. Key words: microelectrode, microsensor, oxygen, fabrication, polarization, calibration, biofilm, wastewater.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».