Digital demodulation system for low-coherence interferometric sensors based on highly birefringent fibers
Notice bibliographique
Résumé
A new type of demodulation system for low-coherence interferometric sensors based on highly birefringent fibers is presented. The optical path delay introduced by the sensor is compensated in four detection channels by quartz crystalline plates of appropriate thickness. The system can be used to decode a single-point sensor with a resolution of 2.5 x 10(-3) or two serially multiplexed sensors with decreased resolution. In a multiplexed configuration each sensor is served by two detection channels. By tilting the quartz plates, we can tune the initial phase shift between interference signals in successive channels to differ by pi/8 or pi/4, respectively, for a single-point or a multiplexed configuration. We transferred the sinusoidal intensity changes into digital pulses by appropriate electronic processing, which eventually allows for an unambiguous phase-shift measurement with a resolution of 1/8 or 1/4 of an interference fringe. The system performance for the measurement of hydrostatic pressure changes and simultaneous changes of hydrostatic pressure and temperature is demonstrated. The pressure sensors are based on side-hole fiber to ensure high sensitivity and an operation range of 2.4 MPa. A new configuration for temperature compensation of hydrostatic pressure sensors is proposed, which is better suited for dynamic pressure measurements. In this configuration the sensing and compensating fibers are located in the same compartment of the sensor housing.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».