Direct surface extraction from 3D freehand ultrasound images
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Surface extraction from ultrasound data is challenging for a number of reasons, including noise and artifacts in the images and non-uniform data sampling. This thesis presents a new technique for the extraction of surfaces from freehand 3D ultrasound data. Most available 3D medical visualization methods fall into two categories: volume rendering and surface rendering. Surface rendering is chosen here because one of the long term goals of this thesis is explicit modelling of organs. Recent progress has been made in surface extraction for a range data or an unorganized data set, by using Radial Basis Functions (RBFs) to represent the whole space with a signed distance function. Instead of using geometric distance as in previous work, this thesis proposes to use pixel intensity directly as a distance function. A new implementation of a freehand 3D ultrasound acquisition system is also introduced in this thesis using a trinocular optical tracking system with light-emitting diodes (LEDs) attached to an ultrasound probe. To calibrate the transformation between the ultrasound image coordinate system and the LED coordinate system, an N-wire calibration phantom was designed. High accuracy is obtained by using multiple images to oversample the calibration points and reduce the level of error. To complete the calibration, geometry of the calibration phantom is measured using a pointing device that is also based on optical tracking. Once calibrated, the 3D freehand ultrasound system is used to scan an object. The images obtained, along with the measured positions, are the inputs of the RBF surface extraction algorithm. First an automatic segmentation method is used to trim extraneous data points to reduce computational demands. Then the data is interpolated by the RBFs, and a surface extracted along isovalued regions. Results using the direct surface extraction method with RBF are shown to successfully extract ultrasound surfaces from thepoint cloud. Surfaces of both phantom and human skin are shown with high fidelity of shape and details. " In summary, this research is the first to represent the set of semi-structured ultrasound pixel data as a single function. From this, we are able to extract realistic surfaces without first reconstructing the irregularly spaced pixels into a regular 3D voxel array. The main advantage of this new approach is to avoid any loss of information normally associated with reconstruction of voxel array.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle