Space charge saturation of Faraday cup detectors used in laser-produced plasmas studies
Notice bibliographique
Résumé
Summary form only given, as follows. Faraday cups are commonly used to measure plasma expansion characteristics in laser-produced plasmas. In its simplest design a Faraday cup consists of a grounded entrance grid and a biased collector plate. As an expanding laser plasma flows into the Faraday cup, the entrance grid, with a mesh size smaller than the local Debye screening length, separates electrons from the ions to be measured and the transmitted ion flux is subsequently collected by the collector plate. When large signals are measured, space charge effects can significantly distort the signals. Such distortion may still lead to apparently reasonable looking ion signal waveforms which are, however, limited in amplitude or truncated from the full correct signal. Thus, the design of Faraday cups should include a consideration of the space charge saturation effects. An analytic approach in one dimension (1D) for calculation of the self consistent fields and effect on the streaming ions in the space charge limited regime is developed to model this process. Based on this approach the ion current modification due to a longitudinal space charge field is investigated theoretically and compared experimentally to measurements for a simple two-electrode ion detector system. The measurements were carried out with carbon plasmas produced by 25 ns KrF laser pulses. In order to maintain the 1D geometry, the size of the gap between the two electrodes in the ion detector is kept small compared to the size of the entrance aperture. The experimental results and comparison to theory will be presented.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».