P1B-11 A 2D-Array for Transcranial Ultrasound Focusing Using Shear-Mode Conversion: A Numerical Study

2007· article· en· W2121114611 sur OpenAlexafffund
Samuel Pichardo, Kullervo Hynynen

Notice bibliographique

RevueProceedings/Proceedings - IEEE Ultrasonics Symposium · 2007
Typearticle
Langueen
DomaineMedicine
ThématiqueUltrasound Imaging and Elastography
Établissements canadiensUniversity of TorontoSunnybrook Health Science Centre
Organismes subventionnairesCanada Research Chairs
Mots-clésShear (geology)Longitudinal waveWavefrontPhysicsAcousticsUltrasoundComputer scienceGeologyWave propagationOptics

Résumé

récupéré en direct d'OpenAlex

An incident ultrasonic acoustic wave with a frequency around 1 MHz creates longitudinal and shear waves inside the skull. Both waves propagate independently through the skull and create two longitudinal waves after the skull: a purely longitudinal wave and a longitudinal-shear-longitudinal wave. The process of the last wave is identified here as the shear-mode conversion (S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> ). The interest of developing ultrasound techniques based on S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> resides in the fact that the transmitted wave due to Sc has less phase-shift. The present study shows the feasibility of focusing ultrasound after the skull using a 2D-array (S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> TX) conceived to take advantage of the Sc and with dimensions comparable to near-flat skull regions such as the anterior part of the frontal bone. The S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> TX array is composed of two columns of 44 times 7 elements each one separated of 3 cm following its length. The configuration in column is aimed to produce an entering wavefront favorable to the shear-mode conversion. Each element is independently driven at 1 MHz and square-shaped with a length of 1.5 mm. The space between elements is 0.4 mm. The length and width of the device are, respectively, 9.7 and 5.9 cm. The new device was compared to a conventional 2D-array (C <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</sub> TX) which has the same specifications of the S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> TX device, with the exception of the inter-column space. The degree of focus steering of both devices was compared for depths of 1, 2, 4 and 6 cm from the inner face of the skull (d <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">fs</sub> ). For each depth, and assuming X and Y perpendicular to the sound propagation axis Z, four focal spots were tested at (x,y)=(0, 0), (2 cm, 0), (0, 2 cm) and (2 cm, 2 cm). A prismatic volume of 10.7 times 6.5 times 0.9 cm, located 1 cm from the device, was used to simulate the skull bone. The required phase of elements was calculated using a back-propagation (BP) method. Tests were done with the corrected phase calculated with only shear-mode BP (S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> BP), only longitudinal BP (L <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</sub> BP) and sum of both back-propagated waves (S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> BP+L <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</sub> BP). The resulting acoustic field for each focal point considered the forward-propagation due to the longitudinal and shear-mode transmissions. S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> TX with S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> BP produced the most focused fields for targets found close to the face of the skull (d <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">fs</sub> = 1 cm) and steered following the X direction. For deeper targets (d/s= 2 cm, 4 cm, 6 cm), the correction S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> BP+L <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">n</sub> BP was more effective to focus ultrasound. For the same targets, the correction S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> BP produced focal zones located closer to the device than expected. Calculation of surface area at -3 dB on XZ and YZ planes indicated that the S <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">c</sub> TX device created more focused fields for most of tested cases, excepting a few cases involving steering following the Y direction. In conclusion, Focusing using shear mode conversion is feasible using a simple device that is compatible with the geometry of the frontal human bone. Using the proposed device, this focusing is limited to tissues located about 1 cm from the inner face of the skull.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,002
score de la tête « metaresearch » (Gemma)0,001
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,181
Score d'incertitude au seuil0,999

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0020,001
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0020,001
Bibliométrie0,0010,002
Études des sciences et des technologies0,0010,000
Communication savante0,0010,001
Science ouverte0,0010,000
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,018
Tête enseignante GPT0,289
Écart entre enseignants0,271 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2007
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueProceedings/Proceedings - IEEE Ultrasonics SymposiumMême sujetUltrasound Imaging and ElastographyTravaux en français237 207