Assessment of platelet activation in several different anticoagulants by the Advia 120 Hematology System, fluorescence flow cytometry, and electron microscopy
Notice bibliographique
Résumé
In vivo platelet activation results are often confounded by activation induced in vitro during the preparative procedures. We measured ex vivo (basal) and in vitro (thrombin-induced) platelet activation in sodium citrate, ethylenediaminetetraacetic acid (EDTA), and Citrate Theophylline Dipyridamole Adenosine (CTAD) whole blood specimens. Determinations were made by measurements of platelet density (mean platelet component: MPC concentration) on the Advia 120 Hematology System. The MPC has been previously shown to correlate with a fluorescence flow cytometric method, also determined in this study, using the surface expression of CD62P. Moreover, platelet shape and structure changes in EDTA and CTAD anticoagulated whole blood specimens were characterized by transmission electron microscopy (TEM). Observations made using the Advia 120 Hematology System platelet density parameter, MPC, in the absence of thrombin were 25.7 +/- 0.9 g/dl, 27.9 +/- 0.9 g/dl and 24.8 +/- 1.2 g/dl in sodium citrate, EDTA and CTAD whole blood specimens, respectively. Addition of thrombin induced a significant change in platelet MPC for sodium citrate (21.9 +/- 1.9 g/dl; p<0.0001) and EDTA (23.2 +/- 0.9 g/dl; p<0.0001) whole blood specimens. In contrast, thrombin had no effect on MPC measured in whole blood taken into CTAD tubes. In vitro fluorescence flow cytometric platelet activation experiments measuring the percentage of platelets expressing anti-CD62P showed increase in sodium citrate specimens from 9.2 +/- 7.0 to 55.5 +/- 23.1 % (p<0.0001) and in EDTA specimens from 1.9 +/- 1.7 to 64.6 +/- 12.4 % (p<0.0001) after addition of thrombin. However, in blood taken into CTAD tubes, there was no significant change. Studies on platelets isolated from whole blood in CTAD showed activation by thrombin indicating that platelets in CTAD, while protected in its presence remained functional upon its removal. When observed by TEM over time, platelets in EDTA appear more activated and contain fewer granules than platelets in CTAD. We conclude that CTAD demonstrates in vitro platelet activation inhibition and may be useful in stabilizing ex vivo platelet activation. The novel platelet activation parameter, MPC, measured by an automated routine hematology system, using customized proprietary software, may be used in conjunction with CTAD, a stabilizing anticoagulant, to measure the ex vivo platelet activation state in whole blood specimens. TEM studies verify shape modifications and simultaneous retention of intracellular granules at early post-venipuncture time periods in CTAD specimens.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».