Picosecond Solvation Dynamics of Coumarin153 in Bis(1-methyl-1H-imidazol-3-ium-3-yl)dihydroborate Cation Containing Room Temperature Ionic Liquid and Ionic Liquid-DMF Mixtures
Notice bibliographique
Résumé
Abstract: Steady state and time-resolved fluorescence behavior of coumarin153(C153) in bis(1-methyl-1H-imidazol-3-ium-3-yl)dihydroborate cation containing room temperature ionic liquid and its mixture with dimethylformamide (DMF) has been investigated. Density functional calculations on the present ionic liquid have been carried out to have ground state structural information of this system. C-H···N and C-H···O hydrogen bonding interactions between cationic and anionic moiety of the present ionic liquid has been observed. Steady state absorption and emission spectral profiles of C153 are found not to be influenced by the polar cosolvent. Time-resolved fluorescence anisotropy experiments show that the rotational motion of the probe becomes faster in presence of DMF. During time dependent dynamic Stokes shift measurements in ionic liquid-DMF mixtures, the average solvation time is found to decrease with the addition of DMF to the ionic liquid. The decrease in both average solvation and rotational time of probe molecule upon gradual addition of polar organic co-solvent is attributed to the lowering of bulk viscosity of the medium.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».