Studies of Water Velocity in the Capillary Fringe: The Point Velocity Probe
Notice bibliographique
Résumé
The point velocity probe (PVP) is a device that can measure groundwater velocity at the centimeter scale, and unlike devices that measure velocity within well screens, the PVP operates while in direct contact with the porous medium. Because of this feature, it was postulated that the PVP could be effective in measuring velocity within the capillary fringe. This hypothesis was tested using a laboratory flow-through cell filled with a medium-fine sand from Canadian Forces Base Borden. The cell was constructed to simulate conditions such that the PVP was positioned from 2.5 cm below the water table to 79 cm above the water table. As the water table was lowered, the PVP gave highly consistent values of velocity over the range equivalent to 2.5 cm below the water table to 44 cm above the water table, the approximate extent of the capillary fringe. The average measured velocity was 11.3 cm/d +/- 11.6%, somewhat higher than that calculated based on the measured discharge through the cell (7.5 cm/d +/- 5.5%). With a further decline in the water table there was a progressive decrease in the measured velocity values, consistent with the declining hydraulic conductivity as the sand material drained. Readings could not be made beyond about 57 cm, where the water content was approximately 75% of saturation. These experiments showed that the PVP is capable of measuring groundwater velocity within the saturated zone above the water table and possibly into the unsaturated zone. Currently, this is the only instrument available with this capability.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».