MétaCan
Menu
Retour à la cohorte
Enregistrement W2129181296 · doi:10.1002/ccd.20281

The clinical development of percutaneous heart valve technology: A position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society of Cardiovascular Angiography and Intervention (SCAI)

2005· article· en· W2129181296 sur OpenAlexaboutno aff
Thomas A. Vassiliades, Peter C. Block, Lawrence H. Cohn, David Adams, Jeffrey Borer, Ted Feldman, David R. Holmes, Warren K. Laskey, Bruce W. Lytle, Michael J. Mack, David O. Williams

Notice bibliographique

RevueCatheterization and Cardiovascular Interventions · 2005
Typearticle
Langueen
DomaineMedicine
ThématiqueCardiac Valve Diseases and Treatments
Établissements canadiensnon disponible
Organismes subventionnairesAmerican College of Cardiology FoundationAmerican Heart Association
Mots-clésMedicineCanadian Cardiovascular SocietyPercutaneousvalvular heart diseaseCardiothoracic surgeryInternal medicineSurgeryMyocardial infarctionAngina

Résumé

récupéré en direct d'OpenAlex

This joint position statement represents the combined efforts of four professional societies (Society of Thoracic Surgeons [STS], American Association for Thoracic Surgery [AATS], American College of Cardiology [ACC], and Society for Cardiovascular Angiography and Interventions [SCAI]), two government agencies (the U.S. Food and Drug Administration [FDA] and the Centers for Medicare and Medicaid Services [CMS]), and numerous industry representatives to assess the foreseeable directions of a class of emerging technologies being developed to enable the percutaneous treatment of cardiac valve dysfunction. Percutaneous heart valve technology (PHVT) is a less invasive means of treating valvular heart disease. The goals of the interdisciplinary group have been to establish cooperation, identify consensus and controversy, and formulate clinical guidelines for the continued development of PHVT. On April 22, 2004, the STS/AATS Committee/Workforce for the Assessment of New Technology (Appendix 1) organized a workshop on PHVT. Included were representatives from the STS, the AATS, the ACC, and SCAI. Also in attendance were representatives from the FDA's Division of Cardiovascular Devices, Circulatory Support and Prosthetic Devices Branch, CMS, and industry representatives (Appendix 2). Clinical aspects of PHVT were initially addressed in small groups with representatives from each of the constituencies followed by a summary report and discussion amongst the entire group. All participants of the workshop and writing group members completed a disclosure questionnaire documenting all outside relationships that might be perceived as real or potential conflicts of interest [1]. Current crucial issues addressed were: 1) trial design, 2) control groups, 3) end points for assessment, 4) rate of technological change, 5) institutional and investigator requirements, and 6) safety. Consideration of these issues is undertaken with the acknowledgement that for most patients with heart valve disease, open cardiac surgical procedures provide an established form of treatment. For decades, percutaneous interventional therapy has been an option for patients with pulmonic [2-4], mitral [5, 6] and aortic valvular disease [7, 8]. For selected patients with pulmonic or mitral stenosis, percutaneous valvuloplasty is the treatment of choice [9, 10]. For patients with calcific aortic stenosis, balloon aortic valvuloplasty (BAV) [11, 12] has been used as a bridge to aortic valve replacement as noted by the current ACC/American Heart Association (AHA) guidelines [13]. Hospital mortality for BAV varies from 3.5% to 13.5%, and as many as 25% of the patients have at least one serious complication [14]. The durability of BAV is limited. Therefore, open aortic valve replacement remains the definitive therapy for aortic stenosis in patients who are viable candidates for surgery. Currently, multiple new concepts for the percutaneous treatment of valvular heart disease are under evaluation in a variety of stages from bench testing to early clinical trials [15]. Most involve either mitral valve repair via annular or leaflet manipulation, or percutaneous valve insertion for pulmonic or aortic valve disease. Using a stent-based valve [16, 17], percutaneous pulmonary valve insertion has been successfully carried out in more than 60 cases, primarily outside the U.S., usually for the treatment of conduit stenosis [18]. However, late follow-up is limited and future trials will need to focus on the issues of patient selection with degenerated conduits, durability and the inability of the device to grow. Although percutaneous aortic valve insertion has been carried out on a compassionate use for extremely high-risk patients [19, 20], significant paravalvular regurgitation and early mortality characterize the experience thus far [21]. Currently, there are no approved percutaneous aortic valve devices in the U.S. The goal of the following discussion is to provide a framework for clinical research directed at further testing of PHVT. The testing of new medical technology usually begins with bench testing (in vitro) and in vivo animal testing, followed by clinical investigation. Initial clinical investigation begins with a feasibility study: a small, unblinded, and uncontrolled trial designed to test safety. Following the feasibility trials, a larger, prospective, controlled trial is performed to evaluate both safety and efficacy (Pivotal trial). The most rigorous design for establishing the safety and effectiveness of new technology is the controlled, randomized trial. It is the consensus of the participants of the Workshop that no adequate historical controls exists for the evaluation of PHVT sufficient to eliminate the influence of confounding variables. Therefore, randomized controlled trials are necessary to evaluate safety and efficacy property for these devices. At each institution participating in clinical trials, the study team should include at least an interventionalist, a cardiac surgeon, a non-interventional clinical investigator charged with monitoring patient welfare, and an echocardiographer. All members of the study team should be charged with ensuring proper patient selection to achieve safety and objectivity. Furthermore, such collaborative interaction will aid trial completion and, it is hoped, lead to improvement in device placement, function, and assessment. Use of PHVT requires skill sets independent of the operator's base discipline, and specific training should be required before engaging in any percutaneous valve procedure. Those individuals eligible for the procedural training should be confined to experienced interventionalists and surgeons. Feasibility studies in adults should be restricted to a small number of high-volume cardiology and cardiac surgery programs where at least 100 to 150 surgical valve operations per year are performed [22]. Participating cardiac surgeons should perform a minimum of 40 to 50 valve repairs or replacements annually [23]. In addition, the surgeon's valve experience should be specific for the device under consideration (i.e., a surgeon with a large volume of aortic valve replacement and minimal mitral valve repair would only qualify for an aortic device study). Although most interventionalists are likely to be cardiologists, or rarely interventional radiologists, surgeons with appropriate training in percutaneous procedures may directly participate, in addition to providing patient selection, guidance, and back-up services. Interventionalists should perform at least 100 percutaneous procedures each year, and have experience with the catheter-based techniques required for PHVT (e.g., trans-septal and/or coronary sinus access techniques) and with the assessment and management of valvular heart disease [24-26]. Clinical trials should also be limited to centers with a proven track record of close collaboration between the aforementioned disciplines and experience in trials. A major problem with all new devices is how to evaluate a first-generation product against the established “gold standard,” in this case the open cardiac surgical procedure. How should a new device that avoids cardiac surgery but perhaps is less effective-especially initially-be best evaluated? At the design stage of a clinical trial it is essential to state clearly the purpose of the study and the specific hypothesis to be evaluated [27]. Randomized controlled trial designs can be broadly viewed as evaluation the superiority or non-inferiority (clinical equivalence) of the test arm with regard to effectiveness. Critical differences exist between these two approaches, which affect sample size, study feasibility, and credibility of conclusions [28]. It is important to point out that it is statistically, and practically, impossible to demonstrate equivalence between two treatment arms, as some differences are always likely to exist. Therefore, a “clinically acceptable” difference (“delta”) between the two treatment arms must be specified at the outset and the null hypothesis constructed such that its rejection supports the claim of non-inferiority (Table 1). Sample size estimation would be most appropriately determined by power calculations for the specific end point and study results published in the literature. Study end points should be chosen that can be assessed objectively by: 1) creating clear criteria for the outcome, 2) collecting the necessary documentation, and 3) having independent core laboratories, blinded to the treatment assignment, adjudicate the cases whenever possible. Meaningful outcome measurements could include components such as death, myocardial infarction, need for surgical repair (including the need for valve replacement when repair was the preoperative intent), stroke or embolic events, hemodynamic deterioration, ejection fraction, measures of reverse remodeling, valvular regurgitation, endocarditis, hemolysis, and functional testing. Although the timing of end point measurements was discussed at the Workshop, the consensus was that it is too early in PHVT development to answer this question. Finally, in any trial designed to evaluate an intervention, “crossovers” are likely to occur. Crossover patients can be analyzed using several methods, including “intent to treat,” “as treated,” and “per protocol” [29, 30]. In addition, a large amount of missing end point data can make interpretation of trial results difficult and threaten the success of the trial. Every effort should be made to collect all data specified in the trial. Additionally, the importance of a knowledgeable and active Data Safety and Monitoring Board cannot be overemphasized. This board should be independent of the investigators, of the company sponsoring the trial, and of any contracted data analysis organizations involved in the trial. The pathophysiologic triad describing mitral regurgitation (MR) is composed of etiology (cause of the disease), valve lesions (resulting from the disease), and valve dysfunction (resulting from the lesion) [31]. These distinctions are relevant because long-term prognosis depends on etiology, whereas surgical treatment strategy-and future PMVR-depends on valve dysfunctions and lesions. Mild to moderate MR is seen in approximately 20% of the general population [32, 33]. The most common causes of MR in Western countries are degenerative, ischemic, and dilated cardiomyopathy [34]. The STS National Adult Cardiac Surgery Database 2003 notes a countrywide mortality for first time elective mitral valve repair of 2.5% (males) to 3.9% (females), and for mitral valve surgery combined with coronary artery bypass these figures are 6.1% (males) to 12.2% (females), respectively [35]. Patients undergoing reoperation are also at increased risk [36]. Mitral valve repair is considered superior to mitral valve replacement because of lower operative mortality, improved late survival, a reduced risk of endocarditis, fewer thromboembolic complications, and better preservation of left ventricular function [37-42]. However, the majority of mitral valve operations done in the U.S. in 2003 remained mitral valve replacement [43]. Individual surgeon experience remains the key factor in predicting the likelihood of mitral valve repair or replacement for any given patient. To discuss patient selection for PMVR for MR and to consider comparative outcomes with surgical approaches, it is possible to consider two classifications: one focusing on etiology and the other on leaflet dysfunction, realizing that both can influence patient outcome. For the purposes of this discussion, we will focus on leaflet dysfunction as opposed to etiology [33]. This classification is based on the opening and closing motions of the mitral leaflets. Patients with type I dysfunction have normal leaflet motion. Mitral regurgitation in these patients is due to annular dilatation or leaflet perforation. There is increased leaflet motion in patients with type II dysfunction with the free edge of the leaflet overriding the plane of the annulus during systole (leaflet prolapse). The most common lesions responsible for type II dysfunction are chordal elongation or rupture and papillary muscle elongation or rupture. Patients with type IIIa dysfunction have restricted leaflet motion during both diastole and systole. The most common lesions are leaflet thickening/retraction, chordal thickening/shortening or fusion, and commissural fusion. The mechanism of MR in type IIIb dysfunction is restricted leaflet motion during systole: left ventricular enlargement with apical papillary muscle displacement due to ischemic or idiopathic cardiomyopathy causes this type of valve dysfunction. Currently, there are two concepts for percutaneous mitral valve repair: 1) partial mitral annuloplasty by device placement in the coronary sinus to reduce the circumference of the posterior mitral annulus; and 2) anterior and posterior leaflet attachment using an edge-to-edge clip or suture [44-46]. Posterior annuloplasty faces multiple anatomic challenges including dilaton of the trigone-to-trigone area [47, 48], leaflet tethering by papillary muscle displacement [49], mitral annular calcification, inability to fix the annuloplasty to the fibrous trigones [50], and the potential for compromise of the circumflex coronary artery. The edge-to-edge repair concept has been used in surgically treated patients, but the best results have been obtained when combined with an annuloplasty [51]. The results of edge-to-edge repair have been suboptimal in patients with restricted leaflet motion (type III dysfunction), including a recent surgical series where it was used in combination with a posterior annuloplasty in patients with ischemic regurgitation [52]. A feasibility study designed to evaluate PMVR with annular remodeling technology should consist of 20 to 30 patients with severe symptomatic MR caused by annular dilation with normal leaflet motion (type I dysfunction) or by restricted leaflet motion (type IIIb dysfunction), or by a combination of these two mechanisms. A feasibility study to evaluate PMVR with leaflet edge-to-edge repair should consist of 20 to 30 patients with excessive leaflet motion (type II dysfunction). These studies will have safety as the primary end point and will assess adverse events including residual (equal or worse) MR, myocardial infarction, stroke, tamponade, coronary artery injury, death, and leaflet damage compromising subsequent mitral valve repair. The secondary end points of the study will include quantitative echocardiographic assessment of MR diminution, left ventricular function, and symptom status. The design of Pivotal trials will need to await safety and durability data from the feasibility study, but will include: 1) comparison of PMVR to open surgical mitral valve repair in patients with types I, II, and IIIb dysfunction; or 2) comparison of PMVR to optimal medical therapy [53] in non-surgical candidates with either end-stage cardiomyopathy and type IIIb severe MR or elderly patients with significant comorbidities and type II dysfunction. Aortic valve replacement is the most common heart valve operation. Aortic stenosis (AS) affects from 2% to 7% of individuals older than 65 years in the U.S., a prevalence that will continue to increase as more people live to older ages [54, 55]. Aortic stenosis is consistently progressive [56-59], and because it occurs in an elderly age group it is often associated with comorbid risk factors and previous bypass surgery [60]. The goals of therapy for patients with AS include both improvement of symptoms and prolongation of life [61]. Percutaneous strategies for the treatment of AS began with percutaneous balloon valvuloplasty, but data from single-center studies and the multicenter National Heart, Lung, and Blood Institute (NHLBI) registry noted only a modest improvement in early hemodynamics, a substantial incidence of peripheral vascular complications, a 30-day mortality of 7%, and a high incidence of restenosis within 6 months [7, 62]. The disappointing results of BAV have led to investigation of the possibility of percutaneous placement of prosthetic aortic valves. Such devices have been used clinically in a small number of cases in high-risk patients [63]. A feasibillity study designed to evaluate PAVR might consist of 20 to 30 patients with severe symptomatic AS (aortic valve area ≤0.70 cm2), or severe aortic valve regurgitation (AR). Initial feasibility trials have treated only AS patients because AR treatment is more problematic for the first generation of PAVR devices. Therefore, it is envisioned that feasibility trials will initially enroll only patients with severe AS. In addition, differences in the age and comorbidity between patients with AS and AR dictate each study population be fairly pure, with a cohort of one or the other but not a mixture. These initial patients should be judged to be at extremely high operative risk as calculated by an established risk scoring system [64-67]. Selection of a risk scoring system as well as the definition of inoperability should be clearly defined in the protocol. Such inoperability will almost always be caused by non-cardiac morbid conditions. In such a feasibility trial it is not acceptable to use such devices for patients who simply refuse open surgery on the basis of personal preference. Study end points will include death, stroke, myocardial infarction, para-prosthetic leak, device migration, symptom status, angiographic gradient, and rehospitalization. Pivotal trials will depend upon the safety data from the feasibility trial, and a variety of control groups may be possible including patients having balloon valvuloplasty and high-risk open surgery. The procedural goal of PHVT is to reliably repair or replace dysfunctional heart valves percutaneously and without the need for cardiopulmonary bypass (CPB). An alternate approach has been to repair or replace valves off-pump through small incisions, thereby simplifying device delivery. Concepts along these lines include anterior and posterior pads connected by a subvalvular cord designed to draw the posterior leaflet and annulus of the mitral valve toward the anterior leaflet [68]; a transatrial off-pump edge-to-edge mitral valve repair [69]; and off-pump AR antegrade through the ascending aorta or retrograde through the left ventricular apex [70]. The minimally invasive surgical approach is an avenue of treating heart valve disease that not only has benefit on its own merit but also supports development of PHVT. At this Workshop, the general considerations of the FDA, as expressed by Bram Zuckerman, Director of Cardiovacular Devices, Office of Device Evaluation (ODE), Center for Devices and Radiologic Health, were as follows, Percutaneous heart valve systems are considered class III devices; they will be reviewed as pre-market approval (PMA) applications [71] and, as such, controlled, randomized clinical trials will be the gold standard for meeting FDA requirements. Industry or independent study should the and of the FDA before any clinical trial for PHVT approval studies may be Although percutaneous devices for the repair or replacement of heart valves they are clearly in an early stage of including the durability of these devices and the potential adverse they may have on subsequent heart surgery. Therefore, one cannot the use of these technologies in patients for published not exist or in of therapy data on safety and effectiveness are from clinical trials. Study candidates should consist of symptomatic patients in long-term is Such a would the of device durability data providing clinically relevant safety and effectiveness clinical trials provide the most of the effectiveness of the treatment. such trials, may be in medical for should not from the importance of these devices in the of a controlled clinical trial of these clinical trials depends upon a to collaboration between cardiology and cardiac surgery. New Technology Assessment on Percutaneous and on Percutaneous in the in Percutaneous Heart Workshop the STS and the the the FDA and Bram Zuckerman, Device Cardiac and Clinical Clinical and and Heart Director of Clinical and Clinical is a with is with is a with and of in and is a with and and report no conflicts of

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,003
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens large)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,583
Score d'incertitude au seuil0,985

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0030,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,024
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,001
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,023
Tête enseignante GPT0,359
Écart entre enseignants0,336 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations23
Publié2005
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueCatheterization and Cardiovascular InterventionsMême sujetCardiac Valve Diseases and TreatmentsTravaux en français237 207