Clinical Magnetic Resonance Imaging of Pancreatic Islet Grafts After Iron Nanoparticle Labeling
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
There is a crucial need for noninvasive assessment tools after cell transplantation. This study investigates whether a magnetic resonance imaging (MRI) strategy could be clinically applied to islet transplantation. The purest fractions of seven human islet preparations were labeled with superparamagnetic iron oxide particles (SPIO, 280 ¼g/mL) and transplanted into four patients with type 1 diabetes. MRI studies (T2*) were performed prior to and at various time points after transplantation. Viability and in vitro and in vivo functions of labeled islets were similar to those of control islets. All patients could stop insulin after transplantation. The first patient had diffuse hypointense images on her baseline liver MRI, typical for spontaneous high iron content, and transplant-related modifications could not be observed. The other three patients had normal intensity on pretransplant images, and iron-loaded islets could be identified after transplantation as hypointense spots within the liver. In one of them, i.v. iron therapy prevented subsequent visualization of the spots because of diffuse hypointense liver background. Altogether, this study demonstrates the feasibility and safety of MRI-based islet graft monitoring in clinical practice. Iron overload (spontaneous or induced) represents the major obstacle to the technique. There is a crucial need for noninvasive assessment tools after cell transplantation. This study investigates whether a magnetic resonance imaging (MRI) strategy could be clinically applied to islet transplantation. The purest fractions of seven human islet preparations were labeled with superparamagnetic iron oxide particles (SPIO, 280 ¼g/mL) and transplanted into four patients with type 1 diabetes. MRI studies (T2*) were performed prior to and at various time points after transplantation. Viability and in vitro and in vivo functions of labeled islets were similar to those of control islets. All patients could stop insulin after transplantation. The first patient had diffuse hypointense images on her baseline liver MRI, typical for spontaneous high iron content, and transplant-related modifications could not be observed. The other three patients had normal intensity on pretransplant images, and iron-loaded islets could be identified after transplantation as hypointense spots within the liver. In one of them, i.v. iron therapy prevented subsequent visualization of the spots because of diffuse hypointense liver background. Altogether, this study demonstrates the feasibility and safety of MRI-based islet graft monitoring in clinical practice. Iron overload (spontaneous or induced) represents the major obstacle to the technique.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle