General considerations for lung function testing
Pourquoi ce travail est-il dans la base ?
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.
Résumé
SERIES “ATS/ERS TASK FORCE: STANDARDISATION OF LUNG FUNCTION TESTING” Edited by V. Brusasco, R. Crapo and G. Viegi Number 1 in this Series ⇓In preparing the joint statements on lung function testing for the American Thoracic Society (ATS) and the European Respiratory Society (ERS), it was agreed by the working party that the format of the statements should be modified so that they were easier to use by both technical and clinical staff. This statement contains details about procedures that are common for many methods of lung function testing and, hence, are presented on their own. A list of abbreviations used in all the documents is also included as part of this statement. All terms and abbreviations used here are based on a report of the American College of Chest Physicians/ATS Joint Committee on Pulmonary Nomenclature 1. The metrology definitions agreed by the International Standards Organization (ISO) are recommended 2 and some important terms are defined as follows. Accuracy is the closeness of agreement between the result of a measurement and the conventional true value. Repeatability is the closeness of agreement between the results of successive measurements of the same item carried out, subject to all of the following conditions: same method, same observer, same instrument, same location, same condition of use, and repeated over a short space of time. In previous documents, the term reproducibility was used in this context, and this represents a change towards bringing this document in line with the ISO. Reproducibility is the closeness of agreement of the results of successive measurements of the same item where the individual measurements are carried out with changed conditions, such as: method of measurement, observer, instrument, location, conditions of use, and time. Thus, if a technician tests a subject several times, this is looking at the …
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
La notice
- Revue
- European Respiratory Journal
- Thématique
- Chronic Obstructive Pulmonary Disease (COPD) Research
- Domaine
- Medicine
- Établissements canadiens
- —
- Organismes subventionnaires
- Hospital for Sick ChildrenUniversity Hospitals Birmingham NHS Foundation TrustMassachusetts General Hospital
- Mots-clés
- ClosenessMedicineReproducibilityLung functionContext (archaeology)Statement (logic)RepeatabilityCredibilityMedical physicsStatisticsLungMathematicsLawInternal medicine
- Résumé présent dans OpenAlex
- oui