Cystatin C Levels in Functionally Anephric Patients Undergoing Dialysis
Notice bibliographique
Résumé
BACKGROUND AND OBJECTIVES: Cystatin C, a low molecular weight protein, is produced by nucleated cells, filtered by glomeruli, and degraded by tubules at a constant rate. Its serum concentration has been proposed as a marker of GFR. Its size should make it dialyzable. It is hypothesized that serum cystatin C levels are influenced by the method and intensity of dialysis received. DESIGN: This is a cross-sectional pilot study of cystatin C in functionally anephric dialysis patients. It was measured predialysis in 14 patients on conventional (3 to 5 h, 3 x wk) hemodialysis; eight on nocturnal hemodialysis (three to seven nights, 6 to 8 h); three on daily hemodialysis (6 d, 1(1/2) to 2(1/2) h); and 10 on automated peritoneal dialysis. All had urea kinetic studies and values for single pool Kt/V (Sp Kt/V), standard weekly Kt/V (Std Kt/V), and protein equivalent of nitrogen appearance (nPNA; g/kg/d). C reactive protein (CRP; mg/L) and thyroid stimulating hormone (TSH; mIU/L) were measured as factors known to influence cystatin C. RESULTS: There was no correlation between cystatin C and Sp Kt/V, but there was a significant inverse linear correlation with Std Kt/V and there were significant differences between treatment modalities in cystatin C levels and in Std Kt/V. The estimation of cystatin C was reliable and stable over 3 to 6 wk and its levels uninfluenced by nPNA, CRP, or TSH. CONCLUSION: Serum cystatin C levels are influenced by the method and intensity of dialysis and may have a role in treatment adequacy monitoring.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».