Chaos Attractors of Ventricular Elastance to Evaluate Cardiac Performance
Notice bibliographique
Résumé
Quantitative evaluation of cardiac function is very important in the clinical application of a ventricular assist device. This article reports a new evaluating method of E max, which is the most reliable parameter to evaluate cardiac function. Fluctuation in the E max time series data was evaluated by the nonlinear mathematical analyzing method including chaos and fractal theory. Experimental goats were anesthetized with halothane inhalation, and left ventricular volume and pressure were measured with other hemodynamic parameters to evaluate E max during various drug administrations. E max was evaluated by two methods. One was the conventional pressure volume loop evaluation and the other was the parameter optimization method without left ventricular volume data. As a result, E max evaluated by the parameter optimization method correlated well with the E max with conventional PV curve. Furthermore, interesting results were obtained. There were rhythmical fluctuations in the E max time series data. By the methodology of Takens, E max time series data was embedded into the phase space and a strange attractor was observed. These results may be important when considering E max evaluation during left ventricular assistance.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».