Characterizing the detector response and testing the performance of a new well counter for neutron coincidence measurements of plutonium in residues.
Notice bibliographique
Résumé
A thermal neutron detector has been developed that integrates the neutron capture medium ({sup 6}LiF) and scintillator (ZnS) into a thin screen, which is coupled to wavelength shifting fiber-optic ribbon. The {sup 6}LiF and ZnS powders are incorporated in a hydrogenous binder. The detector is constructed of alternating layers of the capture/scintillator screen and the fiber-optic ribbon. The scintillation light produced in the ZnS is absorbed and reemitted in the fibers and is transported to photomultiplier tubes (PMTs). The detector is sensitive to gamrna radiation, but the difference in the pulse decay times of gamma-ray and neutron events allows for discrimination using pulse shape analysis (PSA). To determine the feasibility of using PSA with this detector, a number of intrinsic characteristics of the detector have been measured; specifically, the number of photoelectrons produced at the photocathode of the PMT from the average neutron capture event in the screen and the temperature stability of the detector with respect to pulse shape. The number of photons that reach the PMTs was measured with two different PMTs. One was a typical PMT with single-photoelectron resolution, and the other was a Hybrid PMT comprised of a photocathode coupled to a PIN diode with few-photoelectron resolution. The number of photons that reach the PMTs is between 1600 and 2200, which is sufficient for PSA. The sensitivity of pulse shape to temperature has also been evaluated. Although the pulse decay time changes with varying temperature between -25 to +50 C, the normalized detector pulses have approximately the same amplitude around 400 ns. This results in a stable zero-crossing time of the 400-ns delay-line shaped pulse, and thus the PSA is independent of temperature. A four-sided prototype well counter has been built, It has a short neutron die-away time ({tau} < 5 {micro}s), which increases its sensitivity to measurements of {sup 240}Pu by neutron coincidence counting. Because of the high {alpha},n-neutron yields in pyrochemical residues, greater sensitivity is required to measure these materials. Counters with relatively long {tau} (for example, those that use {sup 3}He detectors) will suffer from high accidental coincidence rate. Results with the prototype counter from high-rate measurements, equivalent to those expected from residues, are presented.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».