An investigation of the<sup>109</sup>Cd -ray induced K-x-ray fluorescence (XRF) bone-lead measurement calibration procedure
Notice bibliographique
Résumé
Two sets of phantoms have been used to calibrate a 109Cd y-ray induced K-XRF bone-lead measurement system. Both sets of phantoms are made of plaster of Paris, but the calibration lines are significantly different. This results in a significant difference for the derived concentrations of bone lead for the same person using these two sets of phantoms. This study shows that the different calibration lines are due to the different compositions of the phantoms, which can then be accounted for by adjusting the parameters related to the phantom composition in spectral analysis. Bone-lead concentrations for ten lead-exposed smelter workers were computed before and after analysis modification, and the results show that the bone-lead concentrations for the same person calculated from two sets of phantoms are not significantly different, only after the modifications are incorporated. Through these investigations, it was discovered that a common practice of setting the ratio of the calcium edge amplitude to the coherent scatter amplitude as a constant is only valid when all spectra are acquired at the same system resolution. When there is a change in the resolution between spectra, it has been determined that the ratio of the calcium edge amplitude to the coherent area should instead be used as the constant factor in the analysis program.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».