Enregistrement W2158622604 · doi:10.1093/pch/11.2.75

Transcutaneous bilirubinometry in neonates

2006· article· en· W2158622604 sur OpenAlexaffabout
Koravangattu Sankaran

Notice bibliographique

RevuePaediatrics & Child Health · 2006
Typearticle
Langueen
DomaineMedicine
ThématiqueNeonatal Health and Biochemistry
Établissements canadiensRoyal University Hospital
Organismes subventionnairesnon disponible
Mots-clésMedicineJaundiceKernicterusPediatricsGuidelinePopulationIntensive care medicineSurgery

Résumé

récupéré en direct d'OpenAlex

In recent years, a new risk model for hyperbilirubinemia has emerged. There are several reasons for this. First, delivery of the health care system to the relatively healthy term or near-term infant and mother has changed, with earlier discharge and fewer routine tests (1). Second, physician awareness of the possibility of kernicterus in this population has changed, requiring increased vigilance (2). Third, the tendency toward demedicalization of the relatively healthy breastfed newborn has created the potential for development of severe hyperbilirubinemia (greater than 350 μmol/L). A recent study from Canada (2) concluded that severe hyperbilirubinemia continues to be observed in term and near-term neonates, with significant morbidity. Although jaundice occurs in the majority of newborns and most cases are benign, the newborn with severe jaundice must be identified, carefully followed and, if needed, treated appropriately because of the potential toxicity. Capillary collection of blood by heel puncture or blood collection from venous puncture has been the traditional method of screening and monitoring jaundice in neonates (3). This obviously causes pain and discomfort to infants and anxiety to parents. Transcutaneous bilirubin measurements using BiliChek (Respironics, USA) or other similar devices have been used sporadically in many countries, including the United States and Canada, for the screening of jaundiced infants. The clinical practice guideline that was recently published by the American Academy of Pediatrics (4) stated that there is an urgent need to improve the precision and accuracy of measurement of bilirubin in clinical laboratories. The Academy has called for additional studies on the cost-effectiveness and reproducibility of transcutaneous measurements of total serum bilirubin. Jaundice is first seen in the face of a newborn and generally progresses caudally to the body and the extremities. Visual estimation of jaundice will lead to errors; therefore, screening tools have been developed using noninvasive devices, such as BiliChek, to estimate bilirubin levels, and they have proven to be valid. Although studies are limited, they suggest a measurement within 34 μmol/L to 51 μmol/L when compared with serum bilirubin. A study by Jangaard et al (pages 79–83) evaluated the transcutaneous bilirubin device BiliChek by comparing transcutaneous bilirubin values with total serum bilirubin measurements in well term infants, ill term infants and preterm infants admitted to neonatal intensive care units, with and without phototherapy. The study consisted of two phases: in phase 1, 99 healthy, full-term infants who had not received phototherapy had transcutaneous bilirubin measurement performed simultaneously with heel puncture for serum bilirubin measurement. In phase 2, in 56 infants admitted to neonatal intensive care units, a total of 99 transcutaneous readings were performed at the time that serum bilirubin measurements were ordered for clinical reasons. The operators of the BiliChek device were blinded to the serum bilirubin levels. The authors found that transcutaneous bilirubin measurements were reasonably accurate for measuring bilirubin in term, jaundiced infants not undergoing phototherapy and in those receiving phototherapy if the area of skin was patched from the phototherapy. The BiliChek measurements were unreliable for preterm and ill infants. Jangaard et al should be congratulated for their work. Their study adds to the multiple other studies that are available comparing transcutaneous serum bilirubin measurements with capillary or venous bilirubin collection methods (5–7). Like others, they found that transcutaneous measurement has limitations. For instance, it becomes unreliable after initiation of phototherapy if the skin is not shielded from light because skin is bleached by the light. Their study did not address other important issues, such as varying degrees of skin thickness, skin colour and infants of different ethnic backgrounds, but the authors acknowledge these limitations. Future studies should include larger numbers of infants with larger numbers of measurements so that the reliability, specificity and sensitivity of such devices can be assessed. Infants in Canada are indeed from different ethnic backgrounds; therefore, variability, such as skin colour and thickness, becomes especially important in the Canadian population. Furthermore, it is crucial to investigate the cost-effectiveness of these instruments and the ability to use them for ongoing monitoring of jaundiced infants. If proven effective, these devices can be used to replace the traditional collection of serum from jaundiced infants for the measurement of bilirubin levels.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,169
Score d'incertitude au seuil0,691

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,001
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,001
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,007
Tête enseignante GPT0,258
Écart entre enseignants0,251 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations6
Publié2006
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revuePaediatrics & Child HealthMême sujetNeonatal Health and BiochemistryTravaux en français237 207