Accuracy of Contrast-enhanced US for Differentiating Benign from Malignant Solid Small Renal Masses
Notice bibliographique
Résumé
PURPOSE: To test the hypothesis that qualitative and quantitative features of contrast material-enhanced ultrasonography (US) can be used to differentiate benign from malignant small renal masses. MATERIALS AND METHODS: This is an institutional review board approved, HIPAA-compliant prospective study with written informed consent. Patients with histologically characterized solid small renal masses, excluding lipid-rich angiomyolipomas, underwent qualitative contrast-enhanced US with a combination of three different US machines. A subgroup of patients underwent quantitative contrast-enhanced US. Patients received a bolus injection of 0.2 mL of contrast material for qualitative and quantitative evaluations and were followed for 3 minutes. Two radiologists independently reviewed videotaped qualitative contrast-enhanced US examinations and were blinded to the final diagnoses. Features that were evaluated included lesion vascularity relative to the adjacent cortex in the arterial phase, the presence of a capsule, homogeneity, the pattern of vascularity, and washout. One radiologist separately reviewed a subset of contrast-enhanced US examinations that were performed with all three machines. Parameters of a first-pass time intensity curve were calculated for quantitative analysis. The Mann-Whitney test was used for quantitative parameters, the χ(2) or Fisher exact test was used for qualitative parameters, and κ statistics and Fleiss methodology were used to determine interobserver and intermachine agreement. RESULTS: The study population consisted of 91 patients (35 women and 56 men) with 94 lesions. The mean age was 62 years ± 14 (range, 21-91). Three patients had two lesions each, which were evaluated at two different sessions. There were 26 benign small renal masses (including 18 oncocytomas, seven lipid-poor angiomyolipomas, and one hemangioblastoma) and 68 malignant masses (including 41 clear cell, 20 papillary, and seven chromophobe renal cell carcinomas [RCCs[) that were 1.1-4.0 cm in diameter (mean, 2.7 cm ± 0.9). All patients underwent contrast-enhanced US on the same one machine, and 68 patients were imaged on all three machines. Vascularity was present in all lesions (n = 94) at contrast-enhanced US. Lesion hypovascularity relative to the adjacent cortex in the arterial phase was seen in only malignant lesions by both reviewers; reviewer 1 saw hypovascularity in 24 of 94 lesions (P = .0001), and reviewer 2 saw hypovascularity in 21 of 94 lesions (P = .0006), for a specificity of 100% (95% confidence interval [CI]: 84, 100). This feature had κ values of 0.91 (95%CI: 0.82, 1.00) between the two reviewers and 0.85 (95% CI: 0.72, 0.99) between the three machines. Eighteen of 20 papillary RCCs were hypovascular. Quantitative parameters of area under the receiver operating characteristics curve, peak intensity, wash-in slope of 10%-90% and 5%-45%, and washout slope of 100%-10% and 50%-10% were significantly higher in malignant renal masses (P = .018, P = .002, P = .036, P = .016, P = .001, and P = .005, respectively) than in benign lesions. CONCLUSION: Excluding lipid-rich angiomyolipoma, hypovascularity-which has high interobserver and intermachine agreement-of solid small renal masses relative to the cortex in the arterial phase has 100% specificity (95% CI: 84, 100) for detecting malignancy, most often papillary RCC.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».