Electrical Characteristics of the Junction between PEDOT:PSS and Thiophene-Functionalized Silicon Microwires
Notice bibliographique
Résumé
Thiophene moieties have been attached to Si microwires (Si MWs) by a two-step chlorination/alkylation reaction method. X-ray photoelectron spectroscopy indicated that saturation of the surface occurred after 30 min of reaction time. Electrical measurements using a standard probe station indicated that the junction between individual thiophene-functionalized Si MWs and the conducting polymer poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) ( PEDOT: PSS) became more ohmic as more thiophene was added to the MW surface. Under a light-limited current of 20 nA, representative of operation of Si MWs under 1 Sun illumination conditions, the iR loss of thiophene-n-Si MW/PEDOT-PSS contacts was 20 mV, representing an order of magnitude reduction compared with PEDOT-PSS junctions formed with methyl terminated n-Si MWs. Such iR losses are much less than typical catalytic overpotentials for fuel formation, and hence the thiophene-functionalized Si MW contacts will not limit the performance of a Si MW array-based solar fuels device under 1 Sun illumination.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».