Abstract 98: Higher Volume Endovascular Stroke Centers Have Decreased Times to Treatment
Notice bibliographique
Résumé
Background: Currently, no metric exists for door to arterial puncture time for endovascular treatment in acute ischemic stroke. The aim of this study was to determine the timings of each step of endovascular stroke intervention stratified by the volume of procedures at each center. Methods: We retrospectively reviewed patients from seven institutions undergoing endovascular reperfusion therapies for acute ischemic stroke. Patients with anterior circulation strokes treated less than 8 hours from symptoms onset were included. Demographic, radiographic, angiographic and clinical outcomes were collected. The time interval at each milestone from CT acquisition to reperfusion was recorded. Successful reperfusion was defined as achieving a TICI 2B or 3 score as graded by the operator. Symptomatic hemorrhage was defined as a parenchymal hemorrhage type 2 as defined by ECASScriteria. Centers that performed more than 50 intra-arterial stroke interventions annually were considered high volume (HV) centers. A univariate analysis was performed with the Fisher’s exact test for categorical variables and students t-test for continuous variables to compare HV to lower volume (LV) centers. Variables with a p-value < 0.20 were placed in a binary logistic regression model to determine if there were differences in time to treatment between the two groups. Results: A total of 338 patients with a mean age of 67±14 years and mean NIHSS of 18±5 were included. The mean time from CT imaging to groin puncture was 108±73 minutes. The mean time from groin puncture to the placement of a microcatheter in the thrombus was 41±21 minutes and total procedure time 104±55 minutes. There were no differences in demographics, site of vascular occlusion and hemorrhage rates between high volume and lower volume centers. In univariate analysis, HV centers had a lower time from CT imaging to groin puncture (89±57 minutes vs. 154±84 minutes, p<0.001), procedure time (93±46 minutes vs. 129±65 minutes, p<0.001), final infarct volume (79±82 cm 3 vs. 94±106 cm 3 , p<0.03) and higher reperfusion rates (73% vs. 59%, p<0.01). In binary logistic regression modeling HV centers were found to have a shorter CT acquisition to arterial puncture time [OR 0.991, 95%CI (0.986-0.996), p<0.001] and higher reperfusion rates [OR 1.79, 95% CI (1.04-3.12), p<0.03]. Conclusions: Currently there is variability in the time from CT to arterial puncture and total procedure time across institutions, but HV centers appear to have lower times to treatment. Further study is required to determine how to reduce times to treatment and develop a metric for centers to target.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,007 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,010 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».