MétaCan
Menu
Retour à la cohorte
Enregistrement W2268831889

Experimental Investigation of the Effects of Coagulant Dose and Permeate Flux on Membrane Fouling in a Moving Bed Biofilm Reactor - Membrane Process

2012· dissertation· en· W2268831889 sur OpenAlexaboutno aff
Masoomeh Karimi

Notice bibliographique

RevueUWSpace (University of Waterloo) · 2012
Typedissertation
Langueen
DomaineEnvironmental Science
ThématiqueMembrane Separation Technologies
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésFoulingMembrane foulingMembranePermeationFlux (metallurgy)Process (computing)Membrane reactorChemical engineeringBiofilmChemistryChromatographyMaterials scienceEngineeringOrganic chemistryBiologyBiochemistryComputer science
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

The application of membrane bioreactors (MBRs) to wastewater treatment is increasing due to their ability to operate at high biomass concentrations and to deliver effluents of high quality. The major challenges associated with the application of MBRs is fouling which can shorten the useful life of the membrane, increase in the amount of energy consumed, and the cost for membrane cleaning. The main reasons for fouling are the deposition of solids as a cake layer, pore plugging by colloidal particles, adsorption of soluble compounds and biofouling. Fouling is a particular problem for activated sludge membrane bioreactors (AS-MBRs) since this process deals with liquors having a high concentration of total solids as well as dissolved compounds such as extracellular polymeric substances (EPS). The combination of a moving bed biofilm reactor and a membrane reactor (MBBR-MR) has significant potential. It may be considered as a compact wastewater treatment process which can compensate for the drawbacks of AS-MBRs. Readily biodegradable COD is removed in the MBBR while particulate matter is separated by the membrane. To further reduce the membrane fouling the effects of adding an intermediate coagulation stage was investigated critically on membrane fouling. \nThe present study includes an overall assessment of the performance of a combined MBBR-MR system, based on the chemical oxygen demand (COD) removal efficiency and membrane fouling mechanism. The required test runs were conducted using pilot-scale MBBR and ultra filtration membrane. The pilot MBBR had a working volume of 1.8 m3 with a 60% carrier fill fraction. The MBBR was operated with loading rate of 78 ± 21 g/m2/d (HRT of 4 h). The ultra-filtration was spiral wound and composed of polyethersulfone (PES) with a pore size of 0.03 microns. The MBBR feed was obtained from a final treated wastewater effluent in a food processing plant located in SW Ontario. In this research, ferric chloride was also employed as a coagulant and influences of different coagulant doses and permeate fluxes on membrane fouling were studied. \nBased on the experimental results, it was found that the combination of MBBR with membrane filtration can produce a constant high quality permeate that is appropriate for water reuse purposes. The composition analysis of permeate showed that the stream is free of suspended solids and the average COD turns to 75 ± 25 mg/l. In addition, the MBBR had a SCOD removal of 76% ± 7% which is considered as a reasonable efficiency for a single reactor. \nOperating the membrane without adding coagulant caused rapid fouling in a short time period and the Trans Membrane Pressure (TMP) reached the maximum allowable pressure of 10 psi. However, addition of coagulant was found to decrease the fouling of the membrane as well as increasing the filtration time. The extent of the pre-coagulation effect on membrane fouling was found to strongly depend on the dosage of the coagulant and the MBBR effluent characteristics. A coagulant dose of 400 mg/l with a permeate flux of 7.6 LMH performed the best at reducing membrane fouling. Colloidal fouling was found to be a significant fouling mechanism at low coagulant dose (e.g. 200 mg/l), while cake formation appeared to be mainly responsible for fouling at higher coagulant doses. \nPermeate flux was found to have a significant effect on the fouling of the membrane. The presence of colloidal matters at low fluxes and TSS at higher fluxes were responsible for fouling of the membrane by blocking the pores and formation of the cake layer on the membrane surface, respectively. Then later addition of Dissolved Air Flotation (DAF) inside the factory had a noticeable effect on wastewater characteristics and consequently on fouling of the membrane. A 22% and 31% improvement in TCOD and TSS in the wastewater was observed leading to reduction in the fouling.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,001
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Autre · Signal consensuel: aucune
Score de désaccord entre enseignants0,002
Score d'incertitude au seuil0,007

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0010,001
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0000,001
Études des sciences et des technologies0,0010,000
Communication savante0,0010,001
Science ouverte0,0010,000
Intégrité de la recherche0,0020,001
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,010
Tête enseignante GPT0,213
Écart entre enseignants0,203 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreAutre

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2012
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueUWSpace (University of Waterloo)Même sujetMembrane Separation TechnologiesTravaux en français237 207