Application of portable XRF to the direct analysis of till samples from various deposit types in Canada
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
In this study, results by direct portable XRF (‘pXRF’) on unsieved till samples were compared with those by established laboratory methods (aqua regia or fusion ICP-MS and ICP-ES) on the <0.063-mm fraction to determine if the application of direct pXRF in the field would serve as an acceptable guide for immediate follow-up work. Four test sites in Canada were chosen: the Halfmile Lake Cu-Pb-Zn VMS deposit; the intrusion-hosted W-Mo Sisson deposit; a Pb-Zn Mississippi Valley–type (MVT) deposit in the Pine Point district; and the Triple B kimberlite. Unsieved till samples from the GSC archive collection were used for this study and included samples from background areas, immediately overlying, and at various distances down-ice of each deposit. Ziploc® and Whirl-Pak® bags that were used to contain the samples in the field were tested for their properties of X-ray attenuation and contamination. In general, the performance of pXRF in the four test areas was very good where concentrations of elements of interest (indicator or pathfinder elements) were substantially above detection limits by this technique (in the low ppm range for many elements). The following elements, shown to be useful indicator elements (important constituents of the ore/commodity) or pathfinder elements (those associated with the commodity elements) by the established methodology, showed similar patterns by pXRF on the unsieved material: Zn, Cu, Pb, and As at Halfmile Lake; W, Mo, Cu, Zn, Pb, and As at the Sisson deposit; Zn, Pb, and Fe at Pine Point; and Ca, Sr, Cr, and Ni at Triple B. Pathfinder elements whose concentrations were too low for determination by pXRF include: Ag and Sb at Halfmile Lake; Ag and Cd at Sisson; Cd, S, and Se at Pine Point; and Co, Mg, P, U, and Th at Triple B. The high background for Bi by pXRF, equivalent to c . 50 ppm, and its noisy signal precluded its use at Halfmile Lake and Sisson. Elements which tended to show poor precision (three analyses each sample) by pXRF in some samples due to sample heterogeneity include Sn, V, and W. Mercury was erroneously reported for the majority of samples in the low ppm range by pXRF whereas its concentration in fact was in the low ppb range. Several Pb-, Zn- ( c . 1% Pb, Zn) and Fe-rich (up to 16% Fe) samples demonstrated spectral interferences by: Pb on As, Th and Se; Zn on Cu; and Fe on Co. Results for six till samples analysed in Ziploc® and Whirl-Pak® bags showed that Ziploc® absorbs fewer low-energy photons and hence is preferable for determining light elements such as Si, K and Ca. Supplementary material: Four data-sets are available at http://www.geolsoc.org.uk/SUP18897
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,002 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle