MétaCan
Menu
Retour à la cohorte
Enregistrement W2297768461

GreenLight 180W XPS photovaporization of the prostate: how I do it.

2011· article· en· W2297768461 sur OpenAlexaff
Kevin C. Zorn, Daniel Liberman

Notice bibliographique

RevuePubMed · 2011
Typearticle
Langueen
DomaineMedicine
ThématiqueUrinary Bladder and Prostate Research
Établissements canadiensUniversité de Montréal
Organismes subventionnairesnon disponible
Mots-clésMedicineProstateUrologyLower urinary tract symptomsRetrograde ejaculationTransurethral resection of the prostateProstatectomyUrethral strictureErectile dysfunctionSurgeryInternal medicineUrethraCancer
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

Transurethral resection of the prostate (TURP) is the most common surgical intervention for benign prostatic hyperplasia (BPH), largely due to lower urinary tract symptoms refractory to medical therapy. TURP remains the gold standard for men with prostates sized 30g-80g, while open prostatectomy has been the preferred option for men with glands larger than 80g-100 g and those with other lower urinary tract anomalies such as large bladder stones or bladder diverticula. Unfortunately, these procedures have complications including bleeding (often requiring transfusion in 7%-13% of cases), electrolyte abnormalities (2% TURP syndrome), erectile dysfunction (6%-10%), and retrograde ejaculation (50%-75%). The overall incidence of a second intervention (repeat TURP, urethrotomy and bladder neck incision) has been reported in 12% and 15% of men at 5 and 10 years following TURP. Alternative therapies have been developed with the aim of reducing the level of complications while maintaining efficacy. These include microwave therapy, transurethral needle ablation, and a range of laser procedures (Holmium, Diode, Thulium and 532nm-Greenlight). Photoselective vaporization of the prostate (PVP), initially launched as a 60W prototype, was ultimately introduced to the urology community as a 80W system (American Medical Systems, Minnetonka, Minnesota, USA), has been the predominant device used in clinical trials. This 1st generation used an Nd:YAG laser beam passed through a potassium-titanyl-phosphate (KTP) crystal, halving the wavelength (to 532nm), doubling the laser's frequency, and resulting in a green light. Outcomes have demonstrated a reduced frequency and severity of clinical complications, however it was limited to smaller prostate sizes. In 2006, the 120W lithium triborate laser (LBO), also known as the GreenLight HPS (High Performance System) laser was introduced. This laser utilizes a diode pumped Nd:YAG laser light that is emitted through an LBO instead of a KTP crystal, resulting in a higher-powered 532 nm wavelength green light laser while still using the same 70-degree deflecting, side firing, silica fiber delivery system. The HPS offered an 88% more collimated beam and smaller spot size, resulting in much higher irradiance or power density in its 2 predecessors (60W and 80W) with a beam divergence of 8 versus 15 degrees. The primary aim for this upgrade was to reduce lasing time and improve clinical outcomes while demonstrating the same degree of safety for patients. Limitations of the 120W system included treatment of large prostates greater than 80g-100g and increased cost related to fiber devitrification and fracture. In 2011, the 180W-Greenlight XPS system was introduced, not only with increased power setting to vaporize tissue quicker but significant fiber-design changes. Internal cooling, metal-tip cap protection and FiberLife (temperature sensing feedback), better preserve the integrity of the fiber generally producing a 1-fiber per case expectation. Initial personal experience with XPS has provided comparable outcomes related to morbidity, but with the opportunity to perform a more complete and rapid procedure. Published clinical data with the XPS is unfortunately lacking. The objective of this report is to detail our approach and technique for GreenLight XPS drawing on personal experience with both enucleation and vaporization techniques with various laser technologies along with having performed over 500 GreenLight HPS and 100 XPS procedures. In this regard, recommendations for training are also made, which relate to existing users of the 80W and 120W GreenLight laser as well as to new laser users.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: Observationnel
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,263
Score d'incertitude au seuil0,227

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,067
Tête enseignante GPT0,246
Écart entre enseignants0,178 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations60
Publié2011
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revuePubMedMême sujetUrinary Bladder and Prostate ResearchTravaux en français237 207