Assessing the business case for data centre relocations

2014· article· en· W2301039310 sur OpenAlexaboutno aff
Kristina Welch

Notice bibliographique

RevuecIRcle (University of British Columbia) · 2014
Typearticle
Langueen
DomaineComputer Science
ThématiqueCloud Computing and Resource Management
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésBusiness

Résumé

récupéré en direct d'OpenAlex

Information and Communications Technology (ICT) is a large and growing contributor to the world’s GHG emissions. Left unchecked, annual growth in this sector is expected to continue at 12%, as more and more computing resources and storage are required to support the move to a digital economy and the dematerialization of goods and services. Implicit in this growth is the additional demands for energy to run the storage and computing power systems (data centres). The challenge becomes one of meeting the increasing demand for technology, information storage, and computing power, while reducing the overall impact on the environment. CANARIE has recognized this challenge and is sponsoring research into the opportunities for green or carbon-neutral computing. This report seeks to address two questions: • How can universities and other organizations create and maintain carbon neutral computing facilities that are cost-competitive and scalable? • Should an organization or user move its servers (co-located or rented) to a low-carbon region, and can that move be financed through carbon offsets? Six alternative scenarios for creating a carbon-neutral data centre were developed and evaluated using financial analysis and Net Present Value (NPV), as well as a life cycle assessment and GHG audit to factor in materials, construction, and use-phase emissions. Two key drivers emerged as critical factors for creating low-carbon computing; location and cost. Location - The electricity generation mix in Canada varies considerably from one province to the next, and the dirtiest region (Alberta) is over 70 times as GHG intense as the cleanest (Quebec). Location is therefore a key determinant of how clean or dirty a data centre’s GHG emissions profile is. Data centres located in regions with access to renewable energy provide opportunities for the data centre to tap into the clean energy source, either by connecting to the regional electricity grid or through direct investment in renewable energy projects. Cost - Data centres and the required electrical supply and infrastructure constitute a significant capital investment. Large data centres require a significant amount of electricity, and can therefore justify investments in dedicated renewable energy projects and other forms of direct investment to secure clean electricity. Small data centres, including those evaluated in this report, are less able to justify and support large investments in renewable energy. These owners should therefore leverage indirect investments in clean electricity to achieve carbon-neutrality, be it through Renewable Energy Credits (RECs) or premiums, or carbon offsets. The recommendation, aimed at small and medium sized data centres, is to build in low-carbon regions where opportunities exist to tap into renewable energy sources. Data centres and any renewable energy sources should be connected to the region’s electricity grid in order to manage variability and maximize investments. In this way, investments in renewable energy are spurred on by increasing regional demand while any new sources are connected to the regional grid. The second question deals with existing data centre users (co-located) looking to achieve carbon-neutrality for their operations. Carbon offsets and credits offer opportunities for projects to receive financing to support projects that achieve carbon reductions, however the opportunity to use carbon financing and the decision of whether to move locations must be evaluated on a case-by-case basis. Overall it is recommended that data centres located in low to medium carbon-intensity regions should simply invest in RECs or carbon offsets rather than financing a relocation through carbon credits. Only those data centres that are currently located in dirty or high-carbon intensity areas have a significant opportunity to capitalize on carbon credit financing.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,011
score de la tête « metaresearch » (Gemma)0,035
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,045
Score d'incertitude au seuil0,145

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0110,035
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0000,001
Bibliométrie0,0030,003
Études des sciences et des technologies0,0040,004
Communication savante0,0150,008
Science ouverte0,0030,004
Intégrité de la recherche0,0050,004
Charge utile insuffisante (le modèle a refusé de juger)0,0120,002

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,023
Tête enseignante GPT0,217
Écart entre enseignants0,194 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeSans objet
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2014
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revuecIRcle (University of British Columbia)Même sujetCloud Computing and Resource ManagementTravaux en français237 207