Deep Energy Foundations: Geotechnical Challenges and Design Considerations

2013· dissertation· en· W2301152932 sur OpenAlexaboutno aff
Sherif L. Abdelaziz

Notice bibliographique

RevueVTechWorks (Virginia Tech) · 2013
Typedissertation
Langueen
DomaineEnvironmental Science
ThématiqueMethane Hydrates and Related Phenomena
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésGeotechnical engineeringGeologyEngineeringCivil engineeringConstruction engineering
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

Traditionally, geothermal boreholes have utilized the ground energy for space heating and cooling. In this system, a circulation loop is placed in a small-diameter borehole typically extending to a depth of 200-300 ft. The hole is then backfilled with a mixture of sand, bentonite and/or cement. The loop is connected to a geothermal heat pump and the fluid inside the loop is circulated. The heat energy is fed into the ground for cooling in the summer and withdrawn from the ground for heating in the winter. Geothermal heat pumps work more efficiently for space heating and cooling compared to air-source heat pumps. The reason is ground-source systems use the ground as a constant temperature source which serves as a more favorable baseline compared to the ambient air temperature. A significant cost associated with any deep geothermal borehole is the drilling required for installation. Because Energy Piles perform the dual function of exchanging heat and providing structural support, and are only installed at sites where pile foundations are already required, these systems provide the thermal performance of deep geothermal systems without the additional drilling costs. Low maintenance, long lifetime, less variation in energy supply compared to solar and wind power, and environmental friendliness have been cited as additional Energy Pile advantages. Case studies show that they can significantly lower heating/cooling costs and reduce the carbon footprint. Energy cost savings for typical buildings outfitted with Energy Piles could be as much as 70 percent. The use of Energy Piles has rapidly increased over the last decade, especially in Europe where more than 500 applications are reported. Primary installations have been in Germany, Austria, Switzerland and United Kingdom. Notable projects include the 56-story high Frankfurt Main Tower in Germany, Dock E Terminal Extension at Zurich International Airport in Switzerland and the One New Change building complex in London U.K. Energy piles have seen very little use in the North America, only a handful of completed projects are known; Marine Discovery Center in Ontario, Canada, Lakefront Hotel in Geneva, New York and the Art Stable building in Seattle, Washington. Energy Piles are typically installed with cast-in-place technology (i.e. drilled shafts, continuous flight auger piles, micropiles etc.) while some driven pile applications are also reported. Other types of geotechnical structures in contact with the ground, such as shallow foundations, retaining walls, basement walls, tunnel linings and earth anchors, also offer significant potential for harnessing near-surface geothermal energy. Energy Pile design needs to integrate geotechnical, structural and heat exchange considerations. Geotechnical characteristics of the foundation soils and the level of the structural loads are typically the deciding factors for the selection and dimensioning of the pile foundations. The geothermal heat exchange capacity of an Energy Pile is a key parameter to be considered in design. Thermal characteristics of the ground as well as the heating and cooling loads from the structure need to be considered for the number of piles that will be utilized as heat exchangers. Therefore, the thermal properties of the site need to be evaluated for an Energy Pile application in addition to the traditional geotechnical characterization for foundation design. Energy Piles bring new challenges to geotechnical pile design. During a heat exchange operation, the pile will expand and contract relative to the soil as heat is injected and extracted, respectively. These relative movements have the potential to alter the shear transfer mechanism at the pile-soil interface. Furthermore, the range of temperature increases near the pile surface, though limited by practical operational guidelines, can have a significant effect on pore pressures generation and soil strength. This dissertation provides answers for several research questions including the long-term performance of Energy Piles, the applicability of the thermal conductivity tests to Energy Piles. Furthermore, it presents the results and a detailed discussion about the full scale in-situ thermo-mechanical pile load test conducted at Virginia Tech.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,002
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Théorique ou conceptuel · Signal consensuel: aucune
GenreSignal candidat: Autre · Signal consensuel: aucune
Score de désaccord entre enseignants0,008
Score d'incertitude au seuil0,025

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0010,002
Méta-épidémiologie (sens strict)0,0010,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0010,001
Études des sciences et des technologies0,0010,001
Communication savante0,0020,002
Science ouverte0,0010,001
Intégrité de la recherche0,0010,001
Charge utile insuffisante (le modèle a refusé de juger)0,0080,002

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,021
Tête enseignante GPT0,240
Écart entre enseignants0,219 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeThéorique ou conceptuel
Domainenon disponible
GenreAutre

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations13
Publié2013
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueVTechWorks (Virginia Tech)Même sujetMethane Hydrates and Related PhenomenaTravaux en français237 207