Notice bibliographique
Résumé
Urea is an important nitrogen fertilizer for plant nutrition, but is very susceptible to moisture sorption and caking even at low moisture contents, e.g. 0.25% w/w. When urea particles adsorb moisture followed by drying, crystal bridges form between urea particles. For particles in a bed, this process is called caking. Cakes in stored urea cause a degradation of its quality and value. Investigations of the moisture absorption in beds of manufactured urea particles and adsorption on the external and internal surfaces of urea particles are a necessary step if engineers are to recommend procedures to reduce caking and control inventories. Research on moisture adsorption and cake strength of urea fertilizer has not been sufficiently explored. Only recently have researchers started to devise tests to investigate the crystal bonding between two urea particles. Prior to this research, investigations of the moisture interactions in beds of urea were nearly non-existent. This thesis presents experimental, theoretical and numerical methods to investigate the coupled heat and moisture transfer processes in a bed of urea particles while the bed is exposed to ambient air with changing temperature and humidity. Urea particles are nearly spherical with uniform particle size distribution. The particle size, its internal pore structure and rough crystalline external surface depend on the manufacturing process. In this thesis, two types of urea products are investigated, i.e. prill Georgia urea and granular Terico urea. The rough external surface and internal pore structure of each particle makes the total surface area exposed to water much larger than similar smooth and solid spherical particles. Although Georgia urea has higher external surface area than Terico urea, the latter type has larger total surface area and internal pore volume. For both Terico urea and Georgia, the internal surface area dominates the water sorption process but the external moisture sorption of Georgia urea is more important than that of Terico urea. All the water vapor interaction experiments were carried out with air flow through a test bed because it shortens the duration of each experiment to a few hours in most cases. A series of experiments with step changes in inlet air temperature and humidity for air flow through a urea bed indicated that the measured outlet air temperature and humidity responses, each at a specific air flow rate, reveals a typical exponential or transient time change that can be characterized by a time constant. After formulating the theoretical problem for step changes in the inlet properties, the analytical solutions showed that the time constants of outlet response to whether a temperature step change or a humidity step change are functions of the convection coefficient and air velocity. The predicted outlet air temperature is determined by only one time constant for a temperature step change while it is determined by these two time constants for a humidity step change. A new test cell with sampling test ports was developed to measure the transient moisture uptake of a urea particle bed and its distribution at any time without any interruption of the experiment. A novel particle sampling device, modified from a syringe and pistons, was designed to minimize the particle exposure to ambient air during the moisture content determination using a Karl Fischer titrator. Data from two continuous cyclic step changes in the inlet flow with relative humidities between 4% and 70% at room temperature showed a hysteresis in the isothermal moisture content for only the first cycle. After the second sorption- desorption cycle, the hysteresis disappeared. This implies that the internal pore and particle surface geometry changes are very slow after the first cycle. A new theoretical porous media model was developed for a coupled heat and moisture transport process when humid air flowed uniformly through a large test bed in two coupled computational domains: internal domain (i.e., the particle phase) and the external domain (i.e., the interstitial air space). The moisture migration in two computational domains included: water vapor diffusion inside each particle, and water vapor convection and diffusion in the interstitial air space in the urea particle bed. For energy transport, the temperature was assumed to be uniform inside each particle, but heat convection and conduction between the urea particles and the interstitial air outside particles occurred throughout the bed. Both heat transfer and mass transfer in internal domain and external domain were coupled by the heat and mass convection at the gas-particle interface. The numerical simulation was compared with the data of moisture uptake and showed good agreement implying that the internal moisture diffusion that dominates the moisture uptake process is a very slow process. These above experimental, theoretical and numerical research studies provide a set of information on how urea particles adsorb or desorb moisture from or to ambient air on the external and internal pore surface, which offers a useful suggestion for urea caking prevention and is also a first and necessary step to the study of further caking formation and strength.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».