MétaCan
Menu
Retour à la cohorte
Enregistrement W2319495792 · doi:10.1055/s-0031-1279744

Fatal Aortic Rupture following Endovascular Aneurysm Repair in a Case with Traumatic Thoracic Aortic Injury

2011· article· en· W2319495792 sur OpenAlexaff
Anna Borowiec, Richard Owen, Gord M. Lees

Notice bibliographique

RevueEuropean Journal of Pediatric Surgery · 2011
Typearticle
Langueen
DomaineMedicine
ThématiqueAortic Disease and Treatment Approaches
Établissements canadiensUniversity of Alberta
Organismes subventionnairesnon disponible
Mots-clésMedicineChest radiographMediastinumAortic rupturePresentation (obstetrics)BluntRadiologyAneurysmSurgeryAortic archAortic aneurysmThoracic aortic aneurysmAortaCardiologyRadiography

Résumé

récupéré en direct d'OpenAlex

Case Presentation A previously healthy 16-year-old boy was transferred to a children's tertiary trauma centre after a motor vehicle accident (MVA) in which he was a restrained passenger. On presentation he was unconscious, intubated, and haemodynamically unstable with a heart rate of 140 bpm and a systolic pressure of 85 mmHg. His initial haemoglobin was 100 g/L. The chest radiograph demonstrated a widened mediastinum with effacement of the aortic knuckle consistent with a significant mediastinal haematoma. A CT scan with IV contrast confirmed an aortic injury at the level of the isthmus, 1.5 cm distal to the origin of the left subclavian artery. The patient was admitted to the paediatric intensive care unit and stabilised, with systolic pressures maintained below 100 mmHg. Following consultation with the vascular surgery team the decision was taken to manage the aortic injury with EVAR. The patient's aortic diameters were as follows: ascending aorta above the injury: 18.6 mm×18.6 mm; aorta below the injury: 18.7 mm×19.6 mm; length from the injury to the left subclavian origin: 1.5 cm. The patient was transferred to the local vascular centre where a Cook Zenith single endovascular stent graft (diameter: 26 mm, length: 77 mm, COOK Medical Inc, Bloomington, IN, USA) was inserted under general anaesthesia ([ Fig. 1 ]). Due to the small size of the patient, a left common femoral arterial cutdown was required to gain adequate access. The procedure was otherwise uneventful with good proximal graft deployment just distal to the left subclavian artery margin. Angiographic imaging carried out post procedure confirmed satisfactory graft placement and complete coverage of the aortic defect. 4 days after the EVAR a repeat chest CT with contrast confirmed the good position of the graft with no evidence of contrast extravasation. The patient had also sustained hepatic and renal injuries as well as pulmonary contusions and minor musculoskeletal injuries; all were managed non-operatively. The patient was discharged home on post-admission day 18 in good condition, on a daily 81 mg dose of aspirin. Fig. 1 Angiography at the time of EVAR demonstrating complete exclusion of the pseudoaneurysm and satisfactory graft placement. The patient presented to a peripheral hospital 1 week later with shortness of breath and chest pain, elevated WBC, bilateral lower lobe consolidation and a left pleural effusion on chest radiograph. His presumed diagnosis was pneumonia and he was started on moxifloxacin. After 3 days on antibiotics with no improvement of symptoms, a CT scan of the chest was carried out, which demonstrated aneurysmal dilatation of the thoracic aorta immediately distal to the inferior margin of the stent ([ Fig. 2 ]). The patient was haemodynamically stable at the time of the CT scan and was transferred immediately to the regional vascular centre 1 h away where the graft had originally been inserted. On arrival the patient had sinus tachycardia of 128 bpm and was mildly hypotensive with a systolic blood pressure of 98 mmHg and haemoglobin of 98 g/L. Repair was planned for the following morning using a graft extension to cover the aneurysm; the delay was to allow for correction of the patient's unexplained coagulopathy (INR 2.1). However, within 5 h of admission, the patient became acutely unstable and died, despite all efforts at resuscitation including emergent thoracotomy and open cardiac massage. Intraoperatively a tear involving 60% of the aorta was identified just millimetres distal to the intact graft. Fig. 2 CT at representation with a large pseudoaneurysm at the bottom end of the graft.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,007
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Étude de cas · Signal consensuel: Étude de cas
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,005
Score d'incertitude au seuil0,011

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0010,007
Méta-épidémiologie (sens strict)0,0020,001
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0020,001
Études des sciences et des technologies0,0040,002
Communication savante0,0020,002
Science ouverte0,0010,002
Intégrité de la recherche0,0050,004
Charge utile insuffisante (le modèle a refusé de juger)0,0030,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,049
Tête enseignante GPT0,266
Écart entre enseignants0,216 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeÉtude de cas
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations0
Publié2011
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueEuropean Journal of Pediatric SurgeryMême sujetAortic Disease and Treatment ApproachesTravaux en français237 207