Magnetic imaging-assisted colonoscopy<i>vs</i>conventional colonoscopy: A randomized controlled trial
Notice bibliographique
Résumé
AIM: To compare magnetic imaging-assisted colonoscopy (MIC) with conventional colonoscopy (CC). METHODS: Magnetic imaging technology provides a computer-generated image of the shape and position of the colonoscope onto a monitor to give visual guidance to the endoscopist. It is designed to improve colonoscopy performance and tolerability for patients by enabling visualization of loop formation and endoscope position. Recently, a new version of MIC technology was developed for which there are limited data.To evaluate this latest generation of MIC among experienced rather than inexperienced or trainee endoscopists, a prospective randomized trial was performed using only gastroenterologists with therapeutic endoscopy training. Consecutive patients undergoing elective outpatient colonoscopy were randomized to MIC or CC, with patients blinded to their group assignment. Endoscopic procedural metrics and quantities of conscious sedation medications were recorded during the procedures. The procedure was classified as "usual" or "difficult" by the endoscopist at the conclusion of each case based on the need for adjunctive maneuvers to facilitate endoscope advancement. After more than one hour post-procedure, patients completed a 10 cm visual analogue pain scale to reflect the degree of discomfort experienced during their colonoscopy. The primary outcome was patient comfort expressed by the visual analogue pain score. Secondary outcomes consisted of endoscopic procedural metrics as well as a sedation score derived from standardized dose increments of the conscious sedation medications. RESULTS: Two hundred fifty-three patients were randomized and underwent MIC or CC between September 2011 and October 2012. The groups were similar in terms of the indications for colonoscopy and patient characteristics. There were no differences in cecal intubation rates (100% vs 99%), insertion distance-to-cecum (82 cm vs 83 cm), time-to-cecum (6.5 min vs 7.2 min), or polyp detection rate (47% vs 52%) between the MIC and CC groups. The primary outcome of mean pain score (1.0 vs 0.9 out of 10, P = 0.41) did not differ between MIC and CC groups, nor did the mean sedation score (8.2 vs 8.5, P = 0.34). Within the subgroup of cases considered more challenging or difficult, time-to-cecum was significantly faster with MIC compared to CC, 10.1 min vs 13.4 min respectively (P = 0.01). Sensitivity analyses confirmed a similar pattern of overall findings when each endoscopist was considered separately, demonstrating that the mean results for the entire group were not unduly influenced by outlier results from any one endoscopist. CONCLUSION: Although the latest version of MIC resulted in faster times-to-cecum within a subgroup of more challenging cases, overall it was no better than CC in terms of patient comfort, sedation requirements and endoscopic procedural metrics, when performed in experienced hands.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,004 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,001 |
| Méta-épidémiologie (sens large) | 0,005 | 0,003 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,001 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,003 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,008 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».