Vapor Phase Combustion in Accelerating Rate Calorimetry for Air-Injection EOR Processes
Notice bibliographique
Résumé
Abstract The Accelerating Rate Calorimeter (ARC) is unique for its versatility of operation and application - reliability, validity, and accuracy of results - due to very high adiabaticity. Accelerating Rate Calorimetry is one of the screening tests employed to determine the suitability of a reservoir for air- injection Enhanced Oil Recovery. The ARC is well suited for investigating the reaction mechanisms in the Low-Temperature Range, Negative Temperature Gradient Region, and High-Temperature Range. The ARC provides full time-temperature, time-pressure, and self-heat rate-inverse absolute temperature profiles. An experimental and simulation study was carried out to expand knowledge and interpretation of the data derived from high pressure closed ARC tests. Athabasca bitumen was used for the experimental study in a closed ARC at an initial pressure of 13.8 MPag (2,000 psig) to identify the nature of the oxidation reactions occurring over the different temperature ranges. The simulation component of the study focused on the development of a numerical model that captured the elements of the ARC test. The model incorporated solubility of oxygen and diffusion to control the transfer of oxygen in the liquid oil phase. Mass transfer was found to play an important role at low temperatures up to the temperature where chemical interaction starts to control the distribution of oxygen within the liquid bitumen. Likewise, vaporization of oil and generation of vapor by cracking reactions are also believed to play an important role in air injection processes. Therefore, a vapor phase combustion reaction was integrated into the traditional Belgrave s kinetic model. This modified model predicted the combustion of vaporized oil in the gas phase by flammable limits and rate of diffusion of the vaporized component in the gas phase to become flammable. The results of this study indicated that with the addition of mass transfer to the traditional kinetic model, it was possible to predict the negative temperature gradient region. The result showed solubility and diffusion of oxygen played an important role up to a temperature of 125°C where chemical reactions started to control the distribution of oxygen within the liquid bitumen. The results also showed that vapor phase combustion created a temperature gradient between the gas and bitumen phases when vaporized components became flammable. This showed that the ARC could be an effective tool for understanding liquid and vapor phase reaction and their relative importance in different temperature regimes.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».