The Use of Coagulation as a Pre-treatment to Ultra-filtration Membranes

2007· dissertation· en· W2399895761 sur OpenAlexaboutno aff
Marek J. Ratajczak

Notice bibliographique

RevueUWSpace (University of Waterloo) · 2007
Typedissertation
Langueen
DomaineEnvironmental Science
ThématiqueMembrane Separation Technologies
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésCoagulationFiltration (mathematics)MembraneMedicineChemistryInternal medicineMathematicsStatisticsBiochemistry
DOInon disponible

Résumé

récupéré en direct d'OpenAlex

ABSTRACT
\nWith an increasing population density throughout the world and the current drive to provide fresh water to as many people as possible, innovative methods of providing safe drinking water are in very high demand. In 2002, the United Nations stated in their millennium declaration that one of their priority goals was “to halve, by the year 2015, the proportion of people who are unable to reach or to afford safe drinking water” (UNESCO, 2000). This goal was set with high standards, and will require a great deal of water treatment related research in the short coming years.
\n
\nOver the past two decades, drinking water treatment via membrane filtration has been widely accepted as a feasible alternative to conventional drinking water treatment. Membrane processes are used in environmental, chemical, food, beverage, pharmaceutical, and various other industries for separation applications. Since the early 1990’s, there has been rapid growth in the use of low-pressure hollow fibre membrane processes for the production of drinking water. These membrane systems are increasingly being accepted as feasible technologies for drinking water treatment.
\n
\nLike with any innovative process, it has limitations; the primary limitation being membrane fouling, which is an accumulation of particles on the surface and inside the pores of the membrane surface. Membrane fouling has the ability to reduce the flux, in doing so, requiring a higher pumping intensity to maintain a consistent volume of water being treated. This project investigated chemical coagulation as a pre-treatment to membrane ultra-filtration, with the goal of mitigating fouling impact in order to maintain a consistent permeate flux, while monitoring several water quality parameters before and after treatment such as turbidity, alkalinity, pH and total organic carbon (TOC).
\n
\nTwo different raw water sources were studied: Grand River water taken from the Hidden Valley intake, located in Kitchener, ON, and Lake Ontario water taken from the Woodward Water Treatment Plant in Hamilton, ON. The evaluated coagulants include alum and ferric chloride, which are widely used hydrolyzing metal salt (HMS) coagulants; and three polyaluminum chloride (PACl) products, which are pre-hydrolyzed coagulants formed by the controlled neutralization of aluminum chloride solution.
\n
\nPhase 1 of the project involved the coagulation of water using various aluminum and iron-based coagulants. Synthetic water was used at the outset, followed by the use of raw water obtained from two water treatment plants: one on the Grand River and one on Lake Ontario. A series of jar test trials was conducted to determine optimum coagulant dosages for the removal of NOM. These doses were then used as a baseline for subsequent membrane trials in phase 2 of this project.
\n
\nPhase 2 involved the treatment of raw and coagulated waters with a hollow fibre bench scale UF unit (Zenon Environmental Inc.®, ZeeWeed-1). Membrane trials were performed with the coagulants applied at optimal and sub optimal dosages in order to evaluate the integrated process for mitigation of organic fouling. As all trials were conducted at a constant flowrate, membrane fouling was evaluated by monitoring trans-membrane pressure (TMP) over time. 
\n
\nThe raw and treated water were fractionated to obtain quantitative information on the size components of NOM contributing most to fouling. Results will be presented comparing how the different coagulants affected the concentration of each NOM MW fraction in the raw and treated waters.
\n
\nCollectively, results showed that all four coagulants substantially decreased the rate of TMP increase, particularly with the Grand River water which contained much higher turbidity and TOC concentrations than the Lake Ontario water. During the trials conducted with Grand River, alum performed best, reducing the TMP by 57 % over a 3-day period. The PACl coagulants performed best at reducing the TMP during the Lake Ontario membrane trials; reducing the TMP by 21 % and 19 % for SP 70 and SP respectively. The system’s ability to maintain a permeate turbidity level of 0.1 NTU or lower was met, and TOC removals varied a small amount across the four coagulants, ranging from 45-65 % and 15-35 % for the Grand River and Lake Ontario trials, respectively.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Expérimental (laboratoire) · Signal consensuel: Expérimental (laboratoire)
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,498
Score d'incertitude au seuil0,950

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,020
Tête enseignante GPT0,242
Écart entre enseignants0,222 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeExpérimental (laboratoire)
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations3
Publié2007
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueUWSpace (University of Waterloo)Même sujetMembrane Separation TechnologiesTravaux en français237 207