Randomized Trial Comparing Patient Comfort Between the Oral and Nasal Insertion Routes for Linear Endobronchial Ultrasound
Notice bibliographique
Résumé
BACKGROUND: Linear endobronchial ultrasound (EBUS) is a safe and accurate sampling method for mediastinal adenopathy. The transnasal approach has been proposed to improve patient comfort, but no data compare the oral and nasal routes. The objective was to compare patient comfort during linear EBUS under conscious sedation between the oral and the nasal routes. METHODS: An open-label randomized study comparing the 2 insertion routes for linear EBUS was conducted. Standardized protocols for sedation and topical anesthesia were used. Primary outcome was subjects' comfort measured by a 10-point scale filled 2 hours after the procedure. Willingness to return for a repeat examination, procedural characteristics, complications, and diagnostic yields were also compared. RESULTS: A total of 220 subjects were randomized and allocated to the nasal (n=110) or oral (n=110) route. Twenty-seven subjects in the nasal group (24.5%) had a failed nasal insertion but were analyzed in the nasal group. Procedural characteristics were similar (EBUS duration, doses of sedatives and lidocaine, number of stations sampled, complications). There was no difference between the nasal and oral groups in subjects' comfort (8.3 vs. 8.3, respectively, P=0.99), overall patient satisfaction (8.9 vs. 9.1, respectively, P=0.34), subjects' willingness to return (96% vs. 97%, P=1.00), and physician-reported subject comfort. Rates of adequate specimens and diagnostic yields did not differ significantly between the groups. CONCLUSIONS: For linear EBUS, the nasal and oral approaches confer a similarly high degree of patient comfort with similar complication rates and diagnostic yield. Patient and physician preferences should dictate the route of insertion.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».