Effects of Grasp Frequency on the Dynamics of a Robotic Surgical Grasper1

2016· article· en· W2485248131 sur OpenAlexaboutno aff
Mark J. F. Brown, Trevor K. Stephens, J. J. O’Neill, Timothy M. Kowalewski

Notice bibliographique

RevueJournal of Medical Devices · 2016
Typearticle
Langueen
DomaineMedicine
ThématiqueSurgical Simulation and Training
Établissements canadiensnon disponible
Organismes subventionnairesnon disponible
Mots-clésTestbedComputer scienceHexapodMicrocontrollerSurgical instrumentRobotGRASPInterface (matter)SimulationComputer hardwareEngineeringArtificial intelligenceMechanical engineering

Résumé

récupéré en direct d'OpenAlex

Endoscopic surgical instruments such as the da Vinci EndoWrist® are the interface between surgeon and patient in the burgeoning field of robotic surgery. In the current clinical setting, such tools are being used primarily as an extension of the surgeon's hands. However, more robust features such as online tissue identification may be integrated into the functionality of robotic surgical graspers in the future. For these applications, the tool dynamics should be well understood and modeled across a spectrum of frequencies. The linear model used to characterize the tool is a version proposed by Sie and Kowalewski [1] and is shown in Eq. (1). Refer to Ref. [1] for definition of model parameters(1)θee=K1θ¨m+K2θ˙m+K3θm+K4FmThe robotic surgical grasper analyzed in this experiment was a modified da Vinci EndoWrist tool; the complete design is detailed in Ref. [2]. Grasping is actuated at the proximal end of the tool by two servomotors (Hitec-HS422) interfaced to the tool's spindles. Force data are acquired via two load cells (3132, Phidgets, Inc., Calgary, AB), each adjacent to a servo. Both load cells were calibrated by applying masses to each load cell in a cantilever arrangement and applying regression techniques. The tool was controlled by a microcontroller (mbed NXP LPC1768) with interrupt-capable communication for synchronization with the calibration testbed.A novel calibration testbed was created to provide position data at the tool's end effector. Position was measured with two optical encoders (E5, U.S. Digital, Vancouver, WA). Quadrature encoding was implemented in code resulting in a resolution of 20,000 pulses per revolution at each encoder. Both optical encoder wheels were affixed to separate acrylic disks via a 3D printed spacer. A thin metal rod was inserted into each acrylic disk to allow the surgical tool's grasper to make normal contact with the acrylic disks and thus with the optical encoder wheel. The acrylic disks and encoder wheels were positioned in a uniaxial arrangement about a central steel rod with the use of small-diameter flanged ball bearings. Both rods were then placed in a lathe ensuring uniaxial alignment for the entire duration of testing. A torsion spring with constant k=1×10−4N⋅m/deg was mounted onto the axle at each acrylic disk resulting in a grasping site that provided position data upon a known linear torque (Fig. 1).The tool was placed into the calibration testbed and the end effector secured between the metal axles. The axis of rotation of the jaws was coincident with that of the axles. A frequency sweep was performed with a sampling rate of 1 kHz. Referring to Fig. 2, grasp frequency increased from 0.1 to 5.6 Hz in equally spaced logarithmic intervals. Typical surgical grasps are limited to 3 Hz [3]. Therefore, this range provided six equally spaced frequencies in the regime of typical surgical grasps as well as two frequencies above this typical threshold. Full range of angular motion of the grasping jaws was constrained to 60 deg, with 0 deg corresponding to the fully opened state. Five grasps were performed at each frequency resulting in a total of 40 measured grasps.End-effector position data from the encoders were concatenated with the tool's position, force, and time data and imported into matlab (MathWorks, Inc., Natick, MA) for postprocessing. Position and force at the tool's servomotor were low-pass filtered using a fourth-order Butterworth infinite impulse response (IIR) filter. Applying the filter in postprocessing allowed for zero phase-shift filtering. Velocity and acceleration matrices of each grasp were obtained using robust numerical differentiation techniques proposed by Holoborodko [4]. Linear coefficients K1, K2, K3, and K4 were explicitly calculated using the entire matrices of proximal and end-effector data. The contribution of each individual coefficient with its respective state to the overall response θee,fitted was then determined by numerical integration of each product K1θ¨m,K2θ˙m,K3θm,and K4Fm.The coefficient matrix from Eq. (1) (with units of s2, s, l, and deg/N) was determined to be(2)[K1 K2 K3 K4]=[−2.34×10−6 −3.58×10−4 1.36−55.2]A matrix of θee,fitted was then obtained using Eqs. (1) and (2) with each parameter multiplied by its respective state. For confirmation of the fit, θee,fitted was plotted with θee,measured for one grasp at each frequency as shown in Fig. 3.Figure 3 displays the fitted versus measured values of θee for one grasp at each of the eight frequencies. The curve fit begins to worsen toward the peak of each grasp as the velocity of the end effector diminishes. This may imply that internal stiction of the tool is not ideally accounted for in the current dynamic model, and thus, the K4Fm term could be improved. Beginning with the fourth frequency, θm fails to achieve the full 60 deg range of motion to which the servomotors are commanded.Figure 2 displays the percent contribution of each dynamic term to that of θee,fitted. The K1 and K2 terms appear so small in relative magnitude as to be negligible. At a grasping frequency of 0.1 Hz, roughly 75% of θee,fitted is due to K3θm and 25% is due to K4Fm. As frequency increases, the contribution of the force product decreases marginally. The velocity term increases steadily after 1 Hz reaching a percent contribution of approximately 5% at 5.6 Hz. The acceleration component is notably absent from frequencies below 3.2 Hz and has minimal presence at 5.6 Hz. This data suggest that the velocity component is minimal below grasping frequencies of 1 Hz and that the acceleration component is entirely negligible for frequencies below 5.6 Hz. At these low frequencies, Eq. (1) can be simplified to(3)θee=K3θm+K4FmAs reported by Brown et al., expert surgeons typically employ grasps below 3 Hz. Thus, in the regime below 3 Hz, the model for this tool would appear as Eq. (3). More research should be performed to determine the tool dynamics as they vary among surgical graspers for the determination of a more robust model.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,002
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Observationnel · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,582
Score d'incertitude au seuil0,887

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0010,002
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0000,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0000,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0010,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,019
Tête enseignante GPT0,302
Écart entre enseignants0,283 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeObservationnel
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations1
Publié2016
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueJournal of Medical DevicesMême sujetSurgical Simulation and TrainingTravaux en français237 207