(Invited) Ferrocene-Modified Electroactive Ionic Liquids to Prevent Self-Discharge of Redox-Active Electrolyte Capacitors
Notice bibliographique
Résumé
Introduction: Redox-active electrolyte supercapacitors (RESC) are obtained by dissolving electroactive species in the electrolyte as a mean to increase the energy density of carbon-based capacitors.[1-3] RESCs are most often using aqueous electrolytes due to a higher solubility of redox molecules in water compared to organic solvents. For the same reason, ionic liquids (ILs) have not been extensively studied as electrolyte in RESCs despite the fact that they could present the advantage of an increased maximum operating voltage. So far, a compromise must be done between fast transport and high solubility of the redox molecule (obtained in aqueous electrolytes) and a high cell voltage (obtained with organic solvents and ionic liquids). RESCs may benefit from the development of electroactive electrolytes specifically formulated for this purpose, and which should i) allow high concentrations in redox species, ii) present a high maximum voltage, and iii)include a self-discharge suppression mechanism. This work demonstrates that electroactive ionic liquids, in which a redox moiety is covalently linked to one of the ions, may be used to meet these challenges. Experimental: Electroactive ILs were obtained by modifying the common ionic liquid 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide, [EMIm][NTf2], with ferrocene. The ferrocene redox unit was linked either to the cation ([FcEIm][NTf2]) or the anion ([EMIm][FcNTf]) (Fig. 1). The ionic liquids were then used as the electrolyte in symmetrical cells using activated carbon (80 wt.%) as the active material. The cells were studied to evaluate the energy density and self-discharge to evaluate the effect of the ionic liquid structure on performance. Results and discussion: Cyclic voltammetry was used in first place to evaluate the response of the cells containing an electrolyte composed of 80 wt.% of either [EMIm][NTf2], [FcEIm][NTf2] or [EMIm][FcNTf] ILs in acetonitrile. The oxidation and reduction of the ferrocenyl unit on the IL results in the presence of peaks on the CV curves (Fig. 1). These faradaic reactions increase the amount of energy stored in the device by accumulating charges in the electrolyte which is a the heart of redox-active electrolyte supercapacitors. Galvanostatic charge-discharge (GCD) experiments were carried out to evaluate the energy density of the devices employing the electroactive ionic liquids. The gravimetric specific energy values, based on total weight of both electrodes for the RESCs presented here, are (at I = 2 mA) 13.2 and 9.0 Wh kg-1 for [EMIm][FcNTf] and [FcEIm][NTf2], respectively. These values represent a significant increase from equivalent double-layer devices using either the unmodified ionic liquid [EMIm][NTf2] (Wg = 7.2 Wh kg-1) or the conventional electrolyte 1 M TBAP in CH3CN (Wg = 6.4 Wh kg-1). Self-discharge (SDC) represents a major issue with RESCs because a shuttle discharge mechanism (reduction oxidized species at the negative electrode) adds up to the diffusion-based SDC.[4] The profiles of individual electrodes demonstrate that after an initial decrease due to ohmic drop, the potential of the positive electrode remained constant for three hours. SDC suppression in RESC based on redox IL with the Fc-modified anion is explained by the formation of a film at the positive electrode upon oxidation of [FcNTf]- to [Fc+NTf-]0that prevent the shuttling of the charged species to the negative electrode. Conclusions: The functionalization of an ionic liquid with ferrocene led to high concentrations of redox moieties in the electrolyte (2.4 M) and a large maximum operating voltage (2.5 V). An energy density of up to 13.2 Wh per kg (both electrodes) was obtained which represents an 83 % increase vs. the unmodified ionic liquid. When the ionic liquid’s anion is modified with ferrocene, the self-discharge at the positive electrode is fully suppressed due to the deposition of a film on the electrode. While the rate dependency of the specific energy and stability could be improved, these findings suggest that electroactive ionic liquids are particularly well-suited for use in redox-active electrolyte supercapacitors. References 1) E. Frackowiak et al. Chemsuschem, 5 (2012) 1181-1185; 2) S. Roldan et al. Angew. Chem. Int. Ed., 50 (2011) 1699-1701; 3) S.T. Senthilkumar et al. J. Mater. Chem. A, 1 (2013) 12386-12394; 4) L.B. Chen et al. Energy Environ. Sci., 7 (2014) 1750-1759. Figure 1
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,001 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».