Value of Platelet Esoteric Testing in Laboratory Diagnosis of Platelet Disorders: A Single Center Experience
Notice bibliographique
Résumé
Introduction Patients with inherited and acquired platelet disorders (PD) frequently present with thrombocytopenia and/or mucocutaneous bleeding. Diagnosis of PDs relies on both clinical and laboratory investigation, which encompasses both routine and esoteric platelet testing. The former includes platelet indices, light transmission aggregation (LTA) and platelet function analyzer (PFA-100). The latter includes platelet glycoprotein (GP) assessment by flow cytometry and platelet transmission electron microscopy (PTEM). Several recent studies have demonstrated limited sensitivities of routine platelet testing. It is uncertain if a combination of both routine and esoteric testing can vastly improve the sensitivity. Our goal is to assess the value of platelet esoteric testing and the ultimate sensitivity of laboratory platelet testing in diagnosing PDs. Methods Patients (between year 2012 and 2015) with a known or suspected inherited or acquired platelet disorders were recruited for platelet routine and esoteric testing. Patients' clinical features including ISTH bleeding assessment tool (BAT) scores, platelet count, LTA, PFA-100 ADP (CADP) and epinephrine (CEPI) cartridge closure times, GP expression by flow cytometry and PTEM were performed. All clinical and laboratory variables were collected and statistically analyzed. Results A total of 69 patients (51 females; median age 40 years; range: 8 months to 76 years) were enrolled to this cohort study. By retrospective chart review, 34 patients (49%) had a positive ISTH-BAT score (range 0 to 16). The most common bleeding manifestations (on any degree of severity) were cutaneous bleeding present in 53% of patients (n=37), menorrhagia in 47% of females (n=24), epistaxis in 36% (n=25) and postoperative bleeding in 35% (n=24). Joint, muscle and CNS hemorrhage were the least frequent with 7%, 6% and 1% of patients reporting bleeding in these sites. A total of 22 patients (32%) had thrombocytopenia at the time of their evaluation. Fifty-eight patients (84%) had platelet aggregation studies and of those 15 (26%) had an abnormal study. PFA-100 was performed in 57 patients (83%) of whom 42% (n=24) had prolonged closure times with either ADP or epinephrine. PTEM was performed on all samples. Twenty-seven patients (39%) had abnormal platelet structure including 17 patients who had dense granule deficiency. GP by flow cytometry was performed in 41 patients (59%) and abnormal glycoprotein expression was detected in 6 patients (15%). Of the 55 patients who had all tests performed, 22 patients (40%) had completely normal results. Of the routine tests, only PFA-CEPI or -CADP prolongation is associated with the likelihood of a PTEM abnormality (P<0.005). With the assistance of molecular testing, there were 2 cases of MYH-9 mutation-related platelet disorders, one of RUNX1 mutation-associated thrombocytopenia, one of York platelet syndrome, two of Bernard Soulier variants, one of Quebec syndrome and three of gray platelet syndrome or variants. Bleeding scores showed no statistically significant association with severity of any laboratory abnormalities. Conclusion In this cohort, the sensitivity of routine platelet testing in clinically suspected PDs is about 30-40%. Addition of platelet esoteric testing improves the sensitivity to 60%. However, the degree of platelet laboratory abnormalities do not predict severity of bleeding. The findings of this cohort underscore the importance of clinical assessment and both platelet routine and esoteric testing in investigation of patients with suspected PDs. Disclosures No relevant conflicts of interest to declare.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,002 | 0,003 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,001 | 0,000 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,000 | 0,001 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,002 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».