An Image-Based Device for Accurate Rotational Alignment of the Femoral Component in Total Knee Arthroplasty
Notice bibliographique
Résumé
INTRODUCTION Rotational malalignment of the components in total knee arthroplasty has been linked to patellar maltracking, improper soft tissue balance, abnormal kinematics, premature wear of the polyethylene inlay, and subsequent clinical complications such as anterior knee pain (Barrack et al., 2001; Zihlmann et al., 2005; Lakstein at al., 2010). This study investigates an innovative image-based device that is designed to be used along with an intraoperative Isocentric (ISO-C) 3D imaging C-arm, and the conventional surgical instruments for positioning the femoral component at accurate rotational alignment angles. METHODS The new device was tested on 5 replica models of the femur (Sawbones). Zimmer NexGen total knee replacement instruments were used to prepare the bones. After making the distal transverse cut on the femurs, the trans-epicondylar-axis (TEA) were defined by a line connecting the medial and lateral epicondyles which were marked by holes on the bone models. The 4-in-1 cutting jig was placed and pinned to the bones with respect to the TEA considering 5 different planned rotational alignments: −10°, −5°, 0°, +5°, and +10° (minus sign indicating external and plus sign internal rotation). At this point, the jig was replaced by the alignment device using the head-less pins as the reference, and subsequently an Iso-c 3D image of the bone was acquired using Siemens ARCADIS Orbic C-arm. The image was automatically analyzed using custom software that determined the angle between the TEA and the reference pins (Fig 1). The difference between the angle read from the device and the planned angle was then used to correct the locations of the reference pins through a custom protractor device. Preparation of the bone was continued by placing the 4-in-1 jigs on the newly placed pins. Three-dimensional images of the bones after completion of the cuts were acquired, and the angle between the final cut surface and the TEA was determined. RESULTS The results are listed in Fig 2. The rotational angle read from the image-based device showed misalignments in the range of 0.53° to 5.94° (RMS error=3.67°). After alignments were corrected, the final cut accuracy was in the range of 0.3° to 0.74° (RMS error=0.5°). DISCUSSION The introduced device was very accurate (0.5°) in correcting the rotational alignment of the femoral component. The range of errors for defining the boney landmarks through palpation and visualization is expected to be much larger than was observed in this work (RMS error =3.67°), due to soft tissue obstructions and time pressure during surgery. This would highlight the value of the device even more. The introduced technology is expected to add about 5 to 10 minutes to the surgery at a safe radiation dose comparable to a round transatlantic flight. The surgeon and staff can keep a safe distance during the short imaging time. CONCLUSION The introduced device provides a fast and safe tool for improving component alignments in total knee arthroplasty.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».