MétaCan
Menu
Retour à la cohorte
Enregistrement W2531358542 · doi:10.6000/2369-3355.2016.03.02.4

Microwave Plasma CVD Grown Single Crystal Diamonds - A Review

2016· review· en· W2531358542 sur OpenAlex

Pourquoi ce travail est dans la base

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

venuePublié dans une revue dont le pays d'attache est le Canada.
no affAucune affiliation canadienne : ce travail est invisible pour une base fondée sur la seule affiliation.
Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Notice bibliographique

RevueJournal of Coating Science and Technology · 2016
Typereview
Langueen
DomaineMaterials Science
ThématiqueDiamond and Carbon-based Materials Research
Établissements canadiensnon disponible
Organismes subventionnairesCouncil of Scientific and Industrial Research, IndiaDepartment of Science and Technology, Ministry of Science and Technology, India
Mots-clésPlasmaMaterials scienceMicrowaveSingle crystalChemistryCrystallographyPhysicsComputer scienceNuclear physicsTelecommunications

Résumé

récupéré en direct d'OpenAlex

Diamond offers a range of unique properties, including wide band of optical transmission, highest thermal conductivity, stiffness, wear resistance and superior electronic properties. Such high-end properties are not found in any other material, so theoretically it can be used in many technological applications. But the shortcoming has been the synthesis of the diamond material in the laboratory for any meaningful use. Although microwave plasma chemical vapour deposited (MPCVD) has been in practice since 1980s for the diamond growth but it is in the past 7-8 years that its potential has been realised by the industry due to capability of MPCVD to deposit diamond, pure and fast, for commercial uses. There are many CVD techniques for growing diamond but among them MPCVD can only make single crystal diamond (SCD) effectively. SCD grown by MPCVD is also superior to other forms of diamond produced in the laboratory. For example, SCD is necessary for the best electronic properties - often outperforming the polycrystalline diamond (PCD), the high pressure high temperature (HPHT) diamond and the natural diamond. In many applications the short lateral dimensions of the lab-grown diamond available is a substantial limitation. Polycrystalline CVD diamond layers grown by hot filament CVD solved this problem of large area growth, but the presence of grain boundaries are not appropriate for many uses. On the other hand, there is still limitation in the area over which SCDs are grown by MPCVD, only upto 10-15 mm lateral sizes could have been achieved so far, while there are recipes which rapidly grow several mm thick bulk SCDs. This lateral size limitation of SCDs is primarily because of the small seed substrate dimension. Although natural and HPHT diamonds may not be suitable for the intended application, still they are routinely used as substrates on which SCD is deposited. But the problem lies in the availability of large area natural SCD seeds which are extremely rare and expensive. Moreover, large diamond substrate plates suitable for CVD diamond growth have not been demonstrated by HPHT because of the associated high economic risk in their fabrication and use. Other than lateral dimension, purity of SCD is also very important for technological use. Natural diamond is often strained and defective, and this causes twins and other problems in the CVD overgrowth or fracture during synthesis. In addition, dislocations which are prevalent in the natural diamond substrate are replicated in the CVD layer, also degrading its electronic properties. HPHT synthetic diamond is also limited in size, and generally is of poorer quality in the larger stones, with inclusions being a major problem. There will be much research interest in the next 10 years for the MPCVD growth of SCD. Purer and bigger SCDs will be tried to grow with faster and reproducible MPCVD recipes. Here the MPCVD growth of SCD is being reviewed keeping in mind its huge technological significance in the next decades or so. Discoveries of the commercial productions of silicon, steel, cement different materials have built modern societies but higher scales will be achieved with the advent of lab-grown diamond.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,005
score de la tête « metaresearch » (Gemma)0,003
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Sans objet · Signal consensuel: aucune
GenreSignal candidat: Synthèse · Signal consensuel: Synthèse
Score de désaccord entre enseignants0,832
Score d'incertitude au seuil0,860

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0050,003
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0020,000
Bibliométrie0,0010,002
Études des sciences et des technologies0,0000,002
Communication savante0,0000,000
Science ouverte0,0020,001
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,029
Tête enseignante GPT0,321
Écart entre enseignants0,292 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle