Fuzzy-Logic-Based Control for Induction Motor Drive with the Consideration of Core Loss
Notice bibliographique
Résumé
This paper presents a novel speed control technique of induction motor (IM) drive with the consideration of core loss. Previous works on field-oriented control of induction motor mainly focus on the simplified equivalent circuit by neglecting the core loss. Thus the designed PI and fuzzy constants of the controller without core loss may not work properly under the wide operating range, such as variation of load, variation of reference speed, variation of reference flux, etc. Considering the real time effect of core loss, the present work formulates the non-linear model of the induction motor drive. The complete vector control scheme of the IM drive incorporating the FLC is simulated for a squirrel-cage IM using Matlab/Simulink. The performance of the proposed FLC-based IM drive is investigated and compared to those obtained from the conventional proportional-integral (PI) controller-based drive at various dynamic operating conditions, such as, sudden change in command speed, step change in load, etc. The obtained results confirm the effectiveness of the vector controlled induction motor drive system with the consideration of core loss.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».