Intravascular and hybrid intraoperative stent placement for baffle obstruction in transposition of the great arteries after atrial switch
Notice bibliographique
Résumé
OBJECTIVES: To report our experience with intravascular and hybrid intra-operative stent placement for baffle obstruction in patients with complete transposition of the great arteries (TGA) after the atrial switch (Mustard/Senning) operation. BACKGROUND: Venous baffle obstruction is a challenging complication after atrial switch operation in patients with TGA. Traditional treatment options include intravascular stenting or surgery. METHODS: A retrospective analysis of Mayo Clinic's electronic medical record was completed to identify consecutive pediatric and adult patients with TGA after atrial switch who underwent baffle stent implantation from 1994 to 2015. RESULTS: Overall, 64 patients were referred for cardiac catheterization, in whom 47 (73%) were noted to have hemodynamic and angiographic evidence of baffle obstruction. A total of 20 patients mean age 33 (range: 8-46) years old underwent stent implantation of baffle stenosis at a mean of 33 (range: 7.5-45) years after initial atrial switch operation (Mustard, n = 19; Senning, n = 1). Overall, 27 baffles were stented in 20 patients via the following approaches: intravascular (17); hybrid surgical (3); staged intravascular & hybrid (2). Sites of stent placement were: superior vena cava (SVC) (13); inferior vena cava (IVC) (9); pulmonary venous baffle (5). Three patients had stent placement in the SVC and IVC baffles during the same procedure. Procedural adverse events occurred in 2/22 cases (9%) including creation of unintentional baffle leak (n = 1) and stent migration (n = 1). There was no procedure-related mortality. At follow-up (median 2, range 0.02-10 years), significantly improved NYHA class and mean Doppler baffle gradient were demonstrated (P < 0.05). Mild baffle re-stenosis (mean Doppler gradient; 2-3 mmHg) occurred in two patients who have not required re-intervention. Trivial baffle leak was noted in four patients. Baffle re-intervention was only occurred in one patient. One patient with pre-procedural Class IV symptoms died 3.5 months after stent implantation. CONCLUSIONS: This study is the largest reported experience of intravascular and intra-operative hybrid stent placement for patients with TGA after atrial switch. Transcatheter and minimally invasive hybrid intraoperative surgical stent placement are an effective strategy for relief of systemic and pulmonary venous baffle obstruction. © 2016 Wiley Periodicals, Inc.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,001 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».