“Spontaneous Twiddler's” Syndrome: The Importance of the Device Shape
Notice bibliographique
Résumé
Twiddler's syndrome is caused by patient manipulation of the cardiac implantable device (CID) around its central axis within the pocket, resulting in retraction and dislocation of the electrodes. There are, however, some reports that Twiddler's syndrome may occur spontaneously without the patient's manipulation. This remains contentious as it may be argued that patients may not want to admit to manipulating the CID or may have been unaware of their actions. Recently, we have observed three very similar cases with a "spontaneous" Twiddler's syndrome resulting in lead displacement. All of the three patients denied device manipulation and were not prone to somnambulism or repetitive involuntary motor behaviors. It, therefore, seems highly unlikely that all patients could have manipulated the device in exactly the same way to result in the same postrotational position within the implant pocket. The fact is that the same device was implicated in all these cases in a relatively similar time sequence from implant to recognition of the implantable cardiac defibrillator rotation. We postulate that the unique elongated decision of the Fortify Assura (St. Jude Medical, Minneapolis, MN, USA) ICD makes this device prone to spontaneous rotation as is exemplified by our case series.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,001 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».