MétaCan
Menu
Retour à la cohorte
Enregistrement W2551029062 · doi:10.1182/blood.v120.21.2281.2281

A Comparison of Automated Red Blood Cell Depletion/Exchange to Automated Red Cell Blood Exchange in Sickle Cell Patients.

2012· article· en· W2551029062 sur OpenAlexaffabout
Kevin H.M. Kuo, David Barth

Notice bibliographique

RevueBlood · 2012
Typearticle
Langueen
DomaineMedicine
ThématiqueHemoglobinopathies and Related Disorders
Établissements canadiensUniversity of TorontoUniversity Health Network
Organismes subventionnairesnon disponible
Mots-clésMedicineApheresisHematocritHemoglobinRed CellRed blood cellPCSK9Internal medicine

Résumé

récupéré en direct d'OpenAlex

Abstract Abstract 2281 Introduction: Chronic red blood cell (RBC) exchange transfusion (RBCX) is employed in the prevention and treatment of complications from sickle cell disease (SCD). Although regular automated RBCX by an apheresis device can consistently maintain a low sickle hemoglobin (HbS) percentage at a relatively constant hematocrit level (Hct) with no iron loading, it exposes the patient to significantly more donor erythrocyte units than simple (top-up) transfusion. Since October 2010 the University Health Network, a sickle cell comprehensive care centre in Canada, has started performing automated depletion RBCX with the Caridian Optia Apheresis System. In depletion/exchange, a portion of the patient's RBC is first cytapheresed by the apheresis device prior to the exchange phase of the procedure, with albumin as colloid replacement to maintain intravascular volume and pressure. The clinical effectiveness of depletion/exchange has not been demonstrated in a systematic manner. A retrospective observational cohort study was conducted to investigate the hypothesis that depletion/exchange RBCX, when compared to traditional automated RBCX, will reduce a patient's donor RBC exposure while providing similar hematological and clinical benefit. The laboratory and clinical outcome 1 year before (October 1, 2009) and 1 year after (October 30, 2011) the introduction of depletion/exchange RBCX were compared on a patient-by-patient, rather than on an aggregate, basis. Results: Seven patients, 2 females, 5 males, median age 29 years (range 26 – 38 years), totaling 135 RBCX sessions were examined. Five patients were homozygous for the sickle mutation and 2 were SC compound heterozygotes (HbSC). Stroke was the most prevalent indication (n = 3). Median interval between exchange sessions was 5 weeks (range 4 – 8 weeks). The fraction cell remaining (FCR) was fixed at 20 and did not change when patients were transitioned from non-depleted to depleted exchange. The minimum Hct was reduced to 0.24 in all patients. The inlet speed of the apheresis device and anticoagulant ratio employed were similar across all patients. There was no significant difference in pre-RBCX HbS (or HbS+C in HbSC patients) in 6 patients (P value ranged from 0.0589 to 0.6870). The pre-RBCX HbS was higher with depletion/exchange in 1 patient (P = 0.0071). There was no significant difference in post-RBCX Hct in 5 patients (P value ranged from 0.1056 to 0.8995), and in 2 patients, the mean post-RBCX Hct was lower with depletion/exchange (P = 0.0004 and 0.0148). The mean RBC volume used was reduced by 25 mL/kg/year with depletion/exchange. The mean volume of albumin used was 6.0 ± 2.5 mL/kg per session. Ferritin remained stable throughout the study period (P = 0.2289). None of the patients were on iron chelators. There was no significant difference in mean duration of RBCX session between depletion/exchange and non-depletion exchange in all patients except one. The median duration of one session was 148 ± 51 min. and 147 ± 43 min. in depletion/exchange and non-depletion exchange respectively. A total of 11 adverse events occurred in 135 sessions, with citrate reaction being the commonest (n = 4). There was no significant difference in the rate of adverse event between depletion and non-depletion RBCX (8/74 and 4/61 respectively, P = 0.3874). There was also no incidence of treatment failure, defined as the occurrence of an SCD-related complication in which the RBCX was intended to prevent, in any of the patients during the entire study period, regardless of RBCX method. Conclusion: In this first clinical study of depletion/exchange, this strategy significantly reduced RBC usage in majority of the patients without any negative impact on laboratory and clinical outcome. The use of depletion/exchange reduced RBC usage by 25 mL/kg/year, equivalent to 5 units of packed RBC in a 60 kg person. Further optimization of the technique by modification of the FCR and minimum Hct may yield higher reduction in RBC usage, thereby reducing the risk of exposure to blood products. Disclosures: No relevant conflicts of interest to declare.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,001
score de la tête « metaresearch » (Gemma)0,003
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Essai non randomisé · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,002
Score d'incertitude au seuil0,008

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0010,003
Méta-épidémiologie (sens strict)0,0000,000
Méta-épidémiologie (sens large)0,0010,001
Bibliométrie0,0000,000
Études des sciences et des technologies0,0000,000
Communication savante0,0010,000
Science ouverte0,0000,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0020,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,013
Tête enseignante GPT0,264
Écart entre enseignants0,250 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeEssai non randomisé
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations3
Publié2012
Routes d'admission2
Résumé présentoui

Explorer davantage

Même revueBloodMême sujetHemoglobinopathies and Related DisordersTravaux en français237 207