In Vivo Monitoring of Venous Thrombosis In Mice Using Ultrasonography
Notice bibliographique
Résumé
Abstract Abstract 4214 Deep venous thrombosis is an important cause of morbidity and mortality in clinical medicine. There has been extensive research dedicated to the clinical aspects of venous thrombosis, especially with regards to its diagnosis and treatment. However, animal models studying this phenomenon are scarce and, in most cases, very crude, relying on sacrificing animals to excise the formed thrombi. Developing an in vivo murine model of venous thrombosis, detecting and monitoring thrombi non-invasively as is done in humans can be a powerful tool given our ability to genetically modify the murine genome. Therefore, we developed such a murine model using the Vevo770®, a microimaging ultrasound system previously developed to study the arterial circulation of mice. Two different thrombosis models were employed to generate clots in the inferior vena cava (IVC) of wild type C57Bl6 mice: 1) ligation of the IVC to generate venous stasis and 2) application of Ferric Chloride (FeCl3) to the outer layer of the IVC to injure the endothelium. Using both of these techniques, adequate thromboses were generated in the IVCs of mice as determined pathologically. Other mice were allowed to recover after surgery, and the development of venous thrombosis was assessed by ultrasonography using the Vevo 770®. In order to assess the precision of clot measurements using this novel technique, we then sacrificed the mice and excised the clots. In both models, the measurement of the clot pathologically correlates favorably (R2= 0, 9116 for the ligation model, and R2 = 0,905 for the FeCl3 model) with measurements done by ultrasonography (n=20 for the ligation model, and n=5 for the FeCl3 injury model). In the ligation model, a thrombus develops less than an hour after ligation of the IVC, and the size of the clot increases over time. For example, five hours after the ligation of the IVC, a clot develops and has a cross sectional area of 4,5 mm2. The clot size increases significantly (p=0.001) over time to 6.2 mm2 at 24 hours post ligation (n=20). Treatment of these mice with an anticoagulant (dalteparin at a dose of 200 u/kg) prior to the procedure prevented the development of IVC thrombosis as determined by ultrasonagraphy. These data suggest that the Vevo770® can be used as a reliable technique for the non-invasive assessment of venous thrombosis in mice. Developing a murine model for thrombosis using more accurate, and clinically more relevant techniques such as ultrasonography, is a step towards better understanding the pathophysiology of venous thromboembolism. Figure 1. Clot length correlation using histology and ultrasonography, 24 hrs post ligation of the IVC in 20 mice. R2= 0,9116. Figure 1. Clot length correlation using histology and ultrasonography, 24 hrs post ligation of the IVC in 20 mice. R2= 0,9116. Disclosures: No relevant conflicts of interest to declare.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,001 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,001 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,001 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,001 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».