MétaCan
← tous les travaux

Is the Montreal Cognitive Assessment (MoCA) test better suited than the Mini-Mental State Examination (MMSE) in mild cognitive impairment (MCI) detection among people aged over 60? Meta-analysis

2016· review· pl· 734 citations· W2555002837 sur OpenAlex· 10.12740/pp/45368

Pourquoi ce travail est-il dans la base ?

Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.

Porte sur le CanadaSon objet est le Canada, où que soient ses auteurs.

Aucune affiliation canadienne. Une base fondée sur la seule affiliation (le devis habituel) n'aurait jamais vu ce travail. C'est l'un des travaux qui justifient l'inversion de la base.

Résumé

OBJECTIVES: Screening tests play a crucial role in dementia diagnostics, thus they should be very sensitive for mild cognitive impairment (MCI) assessment. Nowadays, the MiniMental State Examination (MMSE) is the most commonly used scale in cognitive function evaluation, albeit it is claimed to be imprecise for MCI detection. The Montreal Cognitive Assessment (MoCA), was created as an alternative method for MMSE. Aim. MoCA vs. MMSE credibility assessment in detecting MCI, while taking into consideration the sensitivity and specificity by cut-off points. METHODS: A systematic literature search was carried out by the authors using EBSCO host Web, Wiley Online Library, Springer Link, Science Direct and Medline databases. The following medical subject headings were used in the search: mild cognitive impairment, mini-mental state examination, Montreal cognitive assessment, diagnostics value. Papers which met inclusion and exclusion criteria were chosen to be included in this review. At the end, for the evaluation of MoCA 20, and MMSE 13 studies were qualified. Research credibility was established by computing weighted arithmetic mean, where weight is defined as population for which the result of sensitivity and specificity for the cut-off point was achieved. The cut-offs are shown as ROC curve and accuracy of diagnosis for MoCA and MMSE was calculated as the area under the curve (AUC). RESULTS: ROC curve analysis for MoCA demonstrated that MCI best detection can be achieved with a cut-off point of 24/25 (n = 9350, the sensitivity of 80.48% and specificity of 81.19%). AUC was 0.846 (95% CI 0.823-0.868). For MMSE, it turned out that more important cut-off was of 27/28 (n = 882, 66.34% sensitivity and specificity of 72.94%). AUC was 0.736 (95% CI 0.718-0.767). CONCLUSIONS: MoCA test better meets the criteria for screening tests for the detection of MCI among patients over 60 years of age than MMSE.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

La notice

Revue
Psychiatria Polska
Thématique
Dementia and Cognitive Impairment Research
Domaine
Medicine
Établissements canadiens
Organismes subventionnaires
Mots-clés
Montreal Cognitive AssessmentDementiaMini–Mental State ExaminationCognitionReceiver operating characteristicCredibilityPopulationPsychologyCognitive impairmentMedicinePsychiatryInternal medicineDisease
Résumé présent dans OpenAlex
oui