Comparison of 7-Day Storage of Buffy-Coat Derived Platelet Concentrates in an Osmotically Balanced, Interface Stabilizing Platelet Storage Solution and in Plasma.
Notice bibliographique
Résumé
Abstract The use of platelet additive solutions (PAS) for the storage of buffy-coat derived platelet concentrates (PC) could conserve plasma resources and reduce post-transfusion reactions. However, PASs are difficult to handle in a production environment where their relative low viscosity produces an unstable interface between the platelet rich plasma and the red cell pellet. In the current study, a comparison is drawn between buffy-coat derived PCs (4 buffy-coats per pool) stored over 7 days either in plasma or in a novel Viscous PAS that contains 26 % plasma as a by-product of the buffy-coat pooling process. The increased viscosity (1.18 cp at 37°C) of the PAS results in a stable interface during processing. Similar, though more consistent platelet recoveries from buffy-coat pools (BCP) are achieved by the Viscous PAS (77.0 ± 2.6%) as compared to plasma (73.7 ± 5.9 %). These are significantly higher (p<0.05) than recoveries using conventional PASs (64.5 ± 2.1 %). On day 7, platelet concentration, mean platelet volume (MPV), and soluble protein concentration in PCs stored using Viscous PAS (782 ± 87 x 109 cells/L, 9.1 ± 0.5fL, 15.0 ± 1.6 mg/L, respectively) and plasma (840 ± 104 x 109 cells/L, 9.0 ± 0.7fL, 56.09 ± 9.2 mg/L, respectively) were not significantly different from their corresponding day 1 parameters (837 ± 84 x 109 cells/L, 9.1 ± 0.3 fL, 13.5 ± 0.2 mg/L) respectively for Viscous PAS and (830 ± 73 x 109 cells/L, 8.3 ± 0.5 fL, 56.6 ± 6.5 mg/mL) and for plasma. This indicates that Viscous PAS and plasma maintain platelet integrity to a similar degree during 7-day storage. Both storage media maintain pH around 7.20 until day 7. However, the rate of glucose consumption and lactate production of PCs stored in Viscous PAS (0.3365 mmol/L.day, and 0.7591 mmol/L.day) was roughly half that of the rate exhibited by PCs stored in plasma (0.8447 mmol/L.day, and 1.4258 mmol/L.day). As lactate production and glucose consumption are correlated with in vivo platelet recovery (Goodrich et al., 2006) this augurs well for platelets stored in Viscous PAS. Monitoring the extent of shape change (ESC) and morphology scores for PCs in either of the storage media showed no significant difference on day 7. However, CD62 surface expression and the hypotonic shock response (HSR) were significantly better at day 7 (p<0.05) for platelets stored in the Viscous PAS (37.43 ± 3.31% and 75.76 ± 10.95%, respectively) than stored in plasma (58.37 ± 11.71% and 49.79 ± 15.34%, respectively). We have developed a PAS that is easy to handle in a production environment and because of its osmotic balance and realtive viscosity exhibits equivalent or better storage parameters over a 7 day period than does plasma.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,001 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,001 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».