Improving the Thermal Performance and Durability of Historic Masonry Buildings
Notice bibliographique
Résumé
Historic buildings are less energy efficient than modern structures due to the nature of their construction. Although envelope improvements can reduce operating energy, such retrofits can potentially accelerate the deterioration of the historic facade. Consequently, the challenge is to improve the energy performance while maintaining a durable facade.\nThis research proposes a retrofit approach for historic buildings that addresses both energy consumption and durability of the masonry facade. To improve energy performance, an 1879 historic solid masonry home was retrofitted using an innovative Nested Thermal Envelope Design (NTED). An envelope controlling heat, moisture and air movement was constructed around Core and Perimeter zones that were independently operated. Conditioning the entire house provided 36% space heating energy savings below the Ontario Building Code 2012, while turning off the heat to the Perimeter areas increased savings to 68%.\nTo address durability concerns arising from insulating the masonry walls, the use of a vented airspace installed between the masonry and the thermal insulation was explored. The vented airspace at the first field trial increased the drying potential of the historic masonry during the winter when the brick was most vulnerable to freeze-thaw damage. An estimated 1.1 kg/m2/a was removed at South and East walls. The second field trial showed drying between 4.3 kg/m2/a and 5.7 kg/m2/a at the South and 0.08 kg/m2/a wetting at the North. In situ moisture content levels of the brick varied between 10% - 15% while laboratory testing of similar brick revealed a saturated\nmoisture content of 29%. Both field trials showed that the vented airspace\ndrying potential was influenced by facade orientation and solar radiation levels.\nAn alternative way of constructing the airspace was then tested in the laboratory to explore the use of air permeable insulation in lieu of a clear airspace. Walls constructed with rock wool insulation and vent holes, but with no clear airspace, removed between 52% - 90% of moisture, depending on the insulation density and vent hole area. Walls featuring a clear airspace removed between 59% - 95% of moisture. These laboratory tests showed that enough air was able to move through the air permeable insulation thereby improving the drying potential of the walls.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,003 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».