Novel Differential Column Method for Measuring Multicomponent Gas Adsorption Isotherms in NaY Zeolite
Notice bibliographique
Résumé
Separation and purification of gas mixtures using selective adsorbents is widely used in different industries such as gas drying, air separation, and H 2 purification. Equilibrium analysis involving adsorption of binary gas mixtures provides important information related to the adsorbent performance in the separation of gases. In this study, a novel technique termed “differential column technique” was developed for binary isotherm measurement employing streams containing carbon dioxide, carbon monoxide, and ethylene at different compositions. This technique is based on measuring the gas desorption by changing equilibrium pressure conditions. The isotherm curve was generated by summing desorption amounts desorbed at each pressure step. Through the application of this technique, the single-component isotherms of CO 2, CO, and ethylene on zeolite NaY were measured, and the isotherms were compared to the results obtained by a standard gravimetric technique. (The average relative deviation is less than 6%.) The main advantage of the technique is the significant time savings, e.g., one experimental run is required to generate an isotherm compared to multirun experiments using a standard breakthrough technique, in addition to using a simpler experimental setup and generally smaller amount of sample (agglomerated or in a powder form). Another important feature of this technique is the relatively simple extension that allows measurements of gas mixture equilibria. As such, the proposed technique has the potential to be used as a fast screening technique for adsorbent selection based on single-component or mixture analysis. To investigate the consistency of the proposed technique, the binary isotherms of competitive, CO 2 –C 2 H 4, and noncompetitive, CO 2 –CO, mixtures were investigated at different gas compositions. In addition, the effects of sorbate concentrations in the gas phase and interactions with the NaY zeolite active surface were investigated in relation to the adsorption selectivity and capacity, i.e., strong interaction of both CO 2 and ethylene with NaY site resulted in close adsorption selectivity 0.8 ≤ S CO 2 /C 2 H 4 ≤ 1.7, while CO 2 adsorbed more selectively compared to CO, 14 ≤ S CO 2 /CO ≤ 30, as a result of weak CO interaction with the adsorbent sites. Finally, the binary adsorption isotherms and selectivity were predicted by the multisite Langmuir model using the single component’s isotherm parameters. Modest agreements (error ≤ 28%) were obtained between the predicted and experimental results.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,001 | 0,002 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,001 | 0,002 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».