Innovative Hybrid FRP/STEEL Splice Details for Modular Bridge Expansion Joints
Pourquoi ce travail est dans la base
Une base qui oublie comment elle a trouvé un travail ne peut pas être vérifiée. Voici les voies qui ont admis celui-ci.
Notice bibliographique
Résumé
Bridge expansion joints are directly subjected to traffic load, and thus prone to premature fatigue failure.Replacement of components such as modular bridge expansion joints is typically done in a staggered schedule to minimize traffic blockage.Field splices are used to connect the successively installed segments.These splices typically include a combination of field welding or bolting, and experience has shown that they often fail due to fatigue cracking.This thesis reports the investigation of hybrid FRP/steel splice details that avoid the use of field welding.Two configurations have been examined: A GFRP pultruded square tube section, adhesively bonded to the soffit of the spliced beam, consists the moment resisting component in one configuration, whereas the other takes advantage of two series of FRP plates for this purpose.Bolted steel plates splice the beam through web in both cases.The behaviour of these details has been studied extensively under vertical static loads.The effect of several parameters including bond length, FRP end shape, bond surface treatment, adhesive, etc. for each detail has been investigated.A three-dimensional, nonlinear finite element model has been developed for each detail and validated using the experimental results.The bond strength of two adhesives was investigated experimentally using double shear lap splice tests.iii A new method is proposed to analyze the strength of the splice details.This method is based on the results obtained from shear lap splice tests and the verified finite element model developed for the splice detail.The finite element model could thus be used for further parametric studies.More experiments, however, are statistically required before using this model with confidence.The fatigue behaviour of one of the promising splice details has been investigated both experimentally and numerically.A special fatigue test set-up has been designed and used successfully for this purpose.Two fatigue tests to 1,000,000 cycles were run.One failed at 719, 347 cycles and the other survived 1,000,000 cycles.The predicted fatigue life as per the developed model was 871,840 cycles.More experiments are required to understand the fatigue behaviour of the splice detail under various stress ranges.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,001 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,002 |
| Science ouverte | 0,001 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle