A Randomized Comparison Between Ultrasound- and Fluoroscopy-Guided Sacral Lateral Branch Blocks
Notice bibliographique
Résumé
BACKGROUND AND OBJECTIVES: This randomized trial compared ultrasound (US)- and fluoroscopy-guided sacral lateral branch (SLB) blocks. We hypothesized that US would require a shorter performance time. METHODS: Forty patients who required unilateral sacral lateral branch blocks for chronic low back pain were randomized to US or fluoroscopy guidance. Before the performance of the assigned block, an investigator who was not involved in patient care carried out baseline analgesic testing. With US, the dorsal sacroiliac ligament, the sacroiliac joint, and the interosseous ligament were probed with a 22-gauge block needle. The patient was asked to rate the level of discomfort using an 11-point numerical rating scale.After the analgesic test, attending anesthesiologists or supervised trainees carried out the SLB blocks. The local anesthetic agent (lidocaine 2%) was identical in all subjects. In the US group, local anesthetic (1.5 mL) was first injected on the lateral crest at the mid-point between S2 and S3. Subsequently, 2 more injections of 0.5 mL were carried out on the lateral crest, immediately cephalad to S2 and at the S1 level. In the fluoroscopy group, SLB blocks were performed according to a previously described 17-injection technique, which involves 9 skin entry sites and the targeting of the L5 posterior root and S1-S3 sacral lateral branches. A 0.4-mL volume of local anesthetic was deposited at each target point. The performance time, number of needle passes, and the incidence of vascular breach were recorded during the performance of the block.Twenty minutes after the end of local anesthetic injection, the same investigator who performed preblock analgesic testing carried out postblock testing in an identical manner. RESULTS: Compared with fluoroscopy, the US technique was associated with a shorter performance time (267.5 ± 99.3 vs 628.7 ± 120.3 seconds; P < 0.001), fewer needle passes and a lower incidence of vascular breach (0 vs 10 occurrences; P = 0.001). However, the block effect (ie, the proportional decrease in numerical rating scale between preblock and postblock analgesic testing) was similar in both groups. Furthermore, no statistical differences were found in the proportions of patients achieving complete analgesia at each test site. The level of experience (ie, expert vs novice operator) significantly affected performance time with US but not with fluoroscopy. No procedural complications were recorded with either imaging modality during the 30-day follow-up period. CONCLUSIONS: Compared with their fluoroscopic counterparts, US-guided SLB blocks require a shorter performance time as well as fewer needle passes and carry a lower risk of vascular breach.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction machine sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.
Scores du classifieur distillé par catégorie (deux têtes)
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,003 | 0,006 |
| Méta-épidémiologie (sens strict) | 0,002 | 0,001 |
| Méta-épidémiologie (sens large) | 0,004 | 0,002 |
| Bibliométrie | 0,001 | 0,000 |
| Études des sciences et des technologies | 0,001 | 0,002 |
| Communication savante | 0,001 | 0,001 |
| Science ouverte | 0,001 | 0,001 |
| Intégrité de la recherche | 0,003 | 0,003 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,014 | 0,002 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».