ON THE 2D SIMPLIFICATION OF 3D CEMENTLESS HIP STEM NUMERICAL MODELS
Notice bibliographique
Résumé
Introduction Finite element (FE) models are commonly used to analyse the mechanical behaviour of the bone under different conditions. They provide detail information but they can be numerically expensive and this limits their use in cases where large or numerous simulations are required. On the other hand, 2D models show less computational cost but the precision of results depends on the approach used for the simplification. Three 2D approaches are commonly used: models without side-plate (WOSP)[1]; models with variable thickness side-plate and constant cortical thickness (SPCT)[2]; models with side-plate and variable cortical thickness (SPVT)[3]. The aim of this study is to determine which 2D approach reproduces best the FE results obtained with a 3D model involving hip stems. Methods The 2D models were generated by the intersection of the 3D model with the stem symmetry plane. Three approaches were considered to assure 3D-2D correspondence: 1) consider variable thickness for the cortical elements so that their transversal area moment of inertia equals the cross-sectional area moment of inertia from the 3D model (model WOSP); 2) include an additional side-plate with variable thickness to match the area moment of inertia from the 3D model, and consider constant thickness for the cortical bone elements (model SPCT); 3) include the side-plate but consider variable thickness for the cortical bone elements, derived from the 3D model (model SPVT). In all cases, the cancellous bone and stem elements had variable thickness computed so that their transversal area moment of inertia was equal to the cross-sectional area moment of inertia measured in the 3D model. This was done at different levels (Fig.1), providing a thickness distribution for the 2D elements. FE analyses were carried out for the static loading condition simulating stair climbing[4]. All materials were defined as linear isotropic and homogeneous. The post-operative situation where bone ingrowth is achieved was considered, resulting in bonded contact between the bone and the implant. The comparison between the 2D and 3D models was done based on three physical quantities: the Von Mises stresses (σVM); the strain energy density ( U ) and the interfacial shear stress (t) along the stem-bone interface. Results Fig.2 shows the σVM, U and t distributions for the 3D model and in the three 2D models. In general, the values for the three physical quantities were under estimated in all 2D models although the differences were small. However, the maximum values of σVM and U were larger in the 2D models than in the 3D model, whereas maximum t values were under estimated. Discussion It is possible to use 2D simplifications based on the stem symmetry plane to perform FE analyses when large number of simulations is needed or when the computational cost needs to be limited. In this way, a side-plate with variable thickness should be considered to obtain close results to the 3D model, while cortical bone thickness can be kept constant and cancellous bone thickness is varied. For figures/tables, please contact authors directly.
Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.
Comment cette classification a été obtenuedéplier
Prédiction distillée sur la base complète
Imitation des enseignantsNi prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.
Scores Codex et Gemma par catégorie
| Catégorie | Codex | Gemma |
|---|---|---|
| Métarecherche | 0,000 | 0,000 |
| Méta-épidémiologie (sens strict) | 0,000 | 0,000 |
| Méta-épidémiologie (sens large) | 0,000 | 0,000 |
| Bibliométrie | 0,000 | 0,000 |
| Études des sciences et des technologies | 0,000 | 0,000 |
| Communication savante | 0,000 | 0,000 |
| Science ouverte | 0,000 | 0,000 |
| Intégrité de la recherche | 0,000 | 0,000 |
| Charge utile insuffisante (le modèle a refusé de juger) | 0,000 | 0,000 |
Scores machine (provisoires)
Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.
Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.
score_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découleClassification
machine, non validéePrédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.
Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».