MétaCan
Menu
Retour à la cohorte
Enregistrement W2597260518 · doi:10.1182/blood.v112.11.33.33

Randomized, Parallel Group, Multicenter, Multinational Study Evaluating Safety of DU-176b Compared with Warfarin in Subjects with Non-Valvular Atrial Fibrillation

2008· article· en· W2597260518 sur OpenAlexaff
Jeffrey I. Weitz, Stuart J. Connolly, Satoshi Kunitada, James Jin, Indravadan Patel

Notice bibliographique

RevueBlood · 2008
Typearticle
Langueen
DomaineMedicine
ThématiqueAtrial Fibrillation Management and Outcomes
Établissements canadiensMcMaster University
Organismes subventionnairesnon disponible
Mots-clésMedicineWarfarinAtrial fibrillationInternal medicineAdverse effectMyocardial infarctionRandomized controlled trialStroke (engine)MaceData monitoring committeeCardiologySurgeryPercutaneous coronary intervention

Résumé

récupéré en direct d'OpenAlex

Abstract Introduction : The primary objective of this phase II study was to assess the safety of different dose regimens of DU-176b, an oral direct factor Xa inhibitor, in patients with non-valvular atrial fibrillation (AF). Methods : This was a randomized, parallel group, multicenter, multinational, double-blind DU-176b and open-label warfarin safety study in patients with AF (CHADS2 index ≥ 2). Patients were randomly assigned to receive either one of four fixed dose regimens of DU-176b (30 mg qd, 30 mg bid, 60 mg qd or 60 mg bid) or warfarin dose-adjusted to a target international normalized ratio (INR) of 2.0–3.0. for 12 weeks. Investigators, sponsor and study subjects were blinded to DU-176b dose but not to the identity of DU-176b vs. warfarin. Investigators adjusted warfarin doses based on INR values obtained in local laboratories. The INR was determined weekly for 4 weeks and every two weeks thereafter. The primary outcomes were the occurrence of centrally adjudicated major and/or clinically relevant non-major bleeding event, and elevated liver enzymes and/or bilirubin. Secondary outcomes included major adverse cardiovascular events (MACE), a composite of stroke, systemic embolism, acute myocardial infarction, hospitalizations due to cardiovascular condition or cardiovascular death, as well as all other adverse events, including all bleeding events. Results : A total of 1,146 patients were randomized. There were no clinically relevant differences between treatment groups with respect to the demographic data and baseline characteristics. Mean age was 65±8.7 years, 63.3% of patients had a CHADS2 index of 2 and 64.40% were warfarin naïve. The DU-176b 60 mg bid treatment arm was prematurely terminated during the study based on a recommendation by the Independent Data Monitoring Committee (DMC). A total of 180 patients were randomized to this group at the time. The incidence of major and clinically relevant non-major bleeding events was significantly higher in both the DU-176b 60 mg bid and 30 mg bid groups than in those given warfarin. The incidence of major and clinically relevant non-major bleeding events in the DU-176b 30 mg qd and 60 mg qd groups was similar to that in warfarin-treated patients. The time in therapeutic range (TTR) for warfarin-experienced patients was 50.1% and for warfarin naïve patients was 41.8%. There were no significant differences in the number (%) of subjects with persistently elevated ALT, AST, or bilirubin values across the treatment groups. The incidence of stroke was similar across treatment groups (Table). DU-176b 30 mg qd N=235 DU-176b 60 mg qd N=234 DU-176b 30 mg bid N=244 DU-176b 60 mg bid N=180 Warfarin qd N=250 Bleeding, n (%) (95% CI) Major+CR non-major 7 (3.0) (1.2–6.0) 11 (4.7) (2.4–8.3) 19 (7.8) (4.8–11.9)a 19 (10.6) (6.5–16.0)b 8 (3.2) (1.4–6.2) Major 0 (0) (0–1.6) 1 (0.4) (0–2.4) 5 (2.0) (0.7–4.7) 6 (3.3) (1.2–7.1)a 1 (0.4) (0–2.2) All 13 (5.5) (3.0–9.3) 19 (8.1) (5.0–12.4) 32 (13.1) (9.1–18.0) 33 (18.3) (13.0–24.8)b 20 (8.0) (5.0–12.1) Stroke, n (%) (95% CI) 1 (0.4) (0–2.3) 1 (0.4) (0–2.4) 2 (0.8) (0.1–2.9) 2 (1.1) (0.1–4.0) 4 (1.6) (0.4–4.0) Conclusions : DU-176b 30 mg qd and 60 mg qd dose regimens had a safety profile similar to warfarin in patients with AF. Patients treated with the DU-176b 30 mg bid or 60 mg bid regimens had more bleeding events than occurred with warfarin. These results suggest that the DU-176b 30 mg qd or 60 mg qd regimens are safe and well tolerated. A Phase III trial is needed to determine whether DU-176b will provide a suitable replacement for warfarin in AF patients. CR, clinically relevant. aP<0.05, bP=0.002 to warfarin.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction machine sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Le volet Gemma est une étiquette directe du modèle pour chaque travail de la base, lue sur la notice réduite au titre. Le volet Codex est un classifieur appris des 10 348 étiquettes directes de Codex et calibré sur les taux pondérés de l'échantillon; les champs sans appui suffisant ne portent aucun appel Codex. Le mode candidate est l'union des deux volets; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont pas des étiquettes humaines.

score de la tête « metaresearch » (Codex)0,005
score de la tête « metaresearch » (Gemma)0,004
Version: metacan-v3-hybrid-931329e0061cStatut de validation: machine_predicted_unvalidated
Catégories candidatesaucune
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Essai randomisé · Signal consensuel: Essai randomisé
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,005
Score d'incertitude au seuil0,029

Scores du classifieur distillé par catégorie (deux têtes)

CatégorieCodexGemma
Métarecherche0,0050,004
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0030,001
Bibliométrie0,0000,000
Études des sciences et des technologies0,0010,001
Communication savante0,0010,001
Science ouverte0,0010,000
Intégrité de la recherche0,0010,002
Charge utile insuffisante (le modèle a refusé de juger)0,0050,001

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,052
Tête enseignante GPT0,322
Écart entre enseignants0,270 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule source (Gemma direct ou Codex distillé), pas un consensus.

Les modèles n’ont appliqué aucune catégorie : rien dans la taxonomie ne correspondait à ce travail.
Devis d'étudeEssai randomisé
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations28
Publié2008
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueBloodMême sujetAtrial Fibrillation Management and OutcomesTravaux en français237 207