MétaCan
Menu
Retour à la cohorte
Enregistrement W2614033103 · doi:10.1002/mp.12335

Comparison of <sup>192</sup>Ir, <sup>169</sup>Yb, and <sup>60</sup>Co high‐dose rate brachytherapy sources for skin cancer treatment

2017· article· en· W2614033103 sur OpenAlexaff
Habib Safigholi, Ali S. Meigooni, William Y. Song

Notice bibliographique

RevueMedical Physics · 2017
Typearticle
Langueen
DomainePhysics and Astronomy
ThématiqueAdvanced Radiotherapy Techniques
Établissements canadiensSunnybrook HospitalSunnybrook Health Science Centre
Organismes subventionnairesnon disponible
Mots-clésBrachytherapyImaging phantomDosimetryMaterials scienceNuclear medicineMonte Carlo methodPhysicsOpticsRadiation therapyMedicineMathematics

Résumé

récupéré en direct d'OpenAlex

Purpose To evaluate the possibility of utilizing the high‐dose rate ( HDR ) 169 Yb and 60 Co sources, in addition to 192 Ir, for the treatment of skin malignancies with conical applicators. Methods Monte Carlo ( MC ) simulations were used to benchmark the dosimetric parameters of single 169 Yb (4140), 60 Co (Co0.A86), and 192 Ir ( mHDR ‐V2) brachytherapy sources in a water phantom and compared their results against published data. A standard conical tungsten alloy Leipzig‐style applicator (Stand.Appl) was used for determination of the dose distributions at various depths with a single dwell position of the HDR sources. The HDR sources were modeled with its long axis parallel to the treatment plane within the opening section of the applicator. The source‐to‐surface distance ( SSD ) was 1.6 cm, which included a 0.1 cm thick removable plastic end‐cap used for clinical applications. The prescription depth was considered to be 0.3 cm in a water phantom following the definitions in the literature for this treatment technique. Dose distributions generated with the Stand.Appl and the 169 Yb and 60 Co sources have been compared with those of the 192 Ir source, for the same geometry. Then, applicator wall thickness for the 60 Co source was increased (doubled) in MC simulations in order to minimize the leakage dose and penumbra to levels that were comparable to that from the 192 Ir source. For each source‐applicator combination, the optimized plastic end‐cap dimensions were determined in order to avoid over‐dosage to the skin surface. Results The normalized dose profiles at the prescription depth for the 169 Yb‐Stand.Appl and the 60 Co‐double‐wall applicator were found to be similar to that of the 192 Ir‐Stand.Appl, with differences &lt; 2.5%. The percentage depth doses ( PDD ) for the 192 Ir‐, 169 Yb‐ and 60 Co‐Stand.Appl were found to be comparable to the values with the 60 Co‐double‐walled applicator, with differences &lt; 1.7%. The applicator output‐factors at the prescription depth were also comparable at 0.309, 0.316, and 0.298 ( cG y/ hU ) for the 192 Ir‐, 169 Yb‐Stand.Appl, and 60 Co‐double‐wall applicators respectively. The leakage dose around the Stand.Appl for distance &gt; 2 cm from the applicator surface was &lt; 5% for 192 Ir, &lt; 1% for 169 Yb, and &lt; 18% for 60 Co relative to the prescription dose. However, using the double‐walled applicator for the 60 Co source reduced the leakage dose to around 5% of the prescription dose, which is comparable with that of the 192 Ir source. The optimized end‐cap thicknesses for the 192 Ir‐, 169 Yb‐Stand.Appl, and the 60 Co‐double‐wall applicator were found to be 1.1, 0.6, and 3.7 mm respectively. Conclusions Application of the 169 Yb (with Stand.Appl) or the 60 Co source (with double‐wall applicator) has been evaluated as alternatives to the existing 192 Ir source (with Stand.Appl) for the HDR brachytherapy of skin cancer patients. These alternatives enable the clinics that may have 169 Yb or 60 Co sources instead of the 192 Ir source to perform the skin brachytherapy and achieve comparable results. The conical surface applicators must be used with a protective plastic end‐cap to eliminate the excess electrons that are created in the source and applicator, in order to avoid skin surface over‐dosage. The treatment times for the 60 Co source remain to be determined. Additionally, for 169 Yb, the source needs to be changed on monthly basis due to its limited half‐life.

Récupéré en direct depuis OpenAlex et désinversé. Les résumés ne sont pas conservés dans cette base de données : les index inversés représentent 8,6 Go des 9,3 Go de texte de la base, et le serveur dispose de 13 Go libres.

Comment cette classification a été obtenuedéplier

Prédiction distillée sur la base complète

Imitation des enseignants

Ni prévalence calibrée, ni vérité terrain. Validation humaine à venir. Apprise à partir de 10 348 étiquettes directes de Codex et de 10 348 étiquettes directes de Gemma. Le mode candidate est l'union des têtes enseignantes seuillées; le consensus est leur intersection. Ces sorties portent le statut machine_predicted_unvalidated et ne sont ni des étiquettes humaines ni des étiquettes directes de modèles de pointe.

score de la tête « metaresearch » (Codex)0,000
score de la tête « metaresearch » (Gemma)0,000
Version: codex-gemma-dda1882f352aStatut de validation: machine_predicted_unvalidated
Catégories candidatesMéta-épidémiologie (sens strict)
Catégories consensuellesaucune
DomaineSignal candidat: aucune · Signal consensuel: aucune
Devis d'étudeSignal candidat: Autre devis · Signal consensuel: aucune
GenreSignal candidat: Empirique · Signal consensuel: Empirique
Score de désaccord entre enseignants0,864
Score d'incertitude au seuil1,000

Scores Codex et Gemma par catégorie

CatégorieCodexGemma
Métarecherche0,0000,000
Méta-épidémiologie (sens strict)0,0010,001
Méta-épidémiologie (sens large)0,0010,000
Bibliométrie0,0000,000
Études des sciences et des technologies0,0010,001
Communication savante0,0000,000
Science ouverte0,0010,000
Intégrité de la recherche0,0000,000
Charge utile insuffisante (le modèle a refusé de juger)0,0000,000

Scores machine (provisoires)

Les deux têtes enseignantes du modèle étudiant, lues sur ce travail. Un score ordonne la base pour la relecture; il n'affirme jamais une catégorie, et le statut de validation accompagne chaque rangée tel quel.

Scores de référence d'un modèle non mature (critères de maturité non atteints, 7 itérations). Un score ordonne; il n'affirme jamais une catégorie.

Tête enseignante Opus0,024
Tête enseignante GPT0,355
Écart entre enseignants0,332 · la distance entre les deux têtes enseignantes sur ce seul travail
Statut de validationscore_only:v0-immature-baseline · tel quel depuis la passe de notation : score_only signifie que le nombre peut ordonner les travaux, et qu'aucune étiquette de catégorie n'en découle

Classification

machine, non validée

Prédiction automatique; un appel candidat d’une seule tête enseignante, pas un consensus.

Devis d'étudeAutre devis
Domainenon disponible
GenreEmpirique

Le détail, modèle par modèle et score par score, se trouve en fin de page sous « Comment cette classification a été obtenue ».

En bref

Citations41
Publié2017
Routes d'admission1
Résumé présentoui

Explorer davantage

Même revueMedical PhysicsMême sujetAdvanced Radiotherapy TechniquesTravaux en français237 207